Syncronising Controller MCO 350 Operating
Instructions
33-19 Master marker type
Option:
[0]
[1]
[2]
[1]
[3]
33-20 Slave marker type
Option:
[0]
[1]
[2]
[1]
[3]
33-21 Marker window master
Option:
Function:
rising edge of the zero
Select here the type of marker signal for the master drive
track
falling edge of the
zero track
rising edge at I5
falling edge of the
zero track
falling edge at I5
Function:
rising edge of the zero
Select here the type of marker signal for the slave drive
track
falling edge of the
zero track
rising edge at I6
falling edge of the
zero track
falling edge at I6
Function:
Enter how large the permitted tolerance for the occurrence of
the marker is. The factory setting "0" means all markers are
used. At every other setting only those markers are accepted
which are within the window. Example: Marker interval = 30000
and marker window = 1000. Only markers with an interval of
29000 to 31000 is accepted.
®
MG.33.Q1.02 - VLT
is a registered Danfoss trademark
NB!
This parameter is only used in marker synchronis-
ing mode (par. 19-01 = 2 or 5).
NB!
This parameter is only used in marker synchronis-
ing mode (par. 19-01 = 2 or 5).
NB!
This parameter is only used in marker synchronis-
ing mode (par. 19-01 = 2 or 5).
3. Programming
3
41