Danfoss MCO 350 Operating Instructions Manual page 36

Syncronising controller
Table of Contents

Advertisement

3. Programming
32-08 Absolute Encoder Cable Length (Slave)
Option:
32-09 Encoder Monitoring (Slave)
3
Option:
32-10 Direction of rotation
Option:
[1]
[3]
[2]
[4]
32-30 Incremental Signal Type (Master)
Option:
[0]
[1]
[2]
32-31 Incremental Resolution (Master)
Option:
32-32 Absolute Protocol (Master)
Option:
[0]
[1]
[2]
36
Function:
Enter the cable length of the encoder, please note that 300 me-
ters is the maximum.
Function:
Off
No monitoring of encoder hardware.
On
Monitoring of encoder hardware, open- or short-curcuit will
generate error 192.
Function:
standard, position is counting positive when the drive is running
forward.
position is counting negative when the drive is running forward.
as "1", but with opposite sign of the reference to the drive. This
can be used as alternative to swapping two motor phases if di-
rection of motor rotation is wrong.
as "3", but with opposite sign of the reference to the drive. This
can be used as alternative to swapping two motor phases if di-
rection of motor rotation is wrong.
Function:
None
choose if an absolute encoder is used
RS422 (TTL/Line driv-
er).
Sinusoidal 1 Vpp
choose if 1 V peak to peak analog incremental encoder is used.
Function:
Enter the pulses per revolution.
Function:
None
choose if an incremental encoder is used.
SSI.
SSI with filter
choose if the encoder signal is unstable.
MG.33.Q1.02 - VLT
Syncronising Controller MCO 350 Operating
®
is a registered Danfoss trademark
Instructions