Syncstart To A Running Master After Power On - Danfoss MCO 350 Operating Instructions Manual

Syncronising controller
Table of Contents

Advertisement

4. Synchronisation
The following example shows the use of marker synchronisation to compensate for friction slip
that can arise from dropping a box onto Conveyor belt 1. By means of marker correction in the
form of object recognition, the slave belt is controlled so that the product will always be placed
right in the middle of the box, even if the box itself is not centrally positioned in its conveyor
compartment.
4
Illustration 4.11: Conveyor belt with marker synchronisation

4.8.2. SyncStart to a Running Master after Power ON

If the slave is synchronised to a running master drive, the slave automatically synchronises its
position to the master. After at least one slave marker and one master marker have been detected,
the marker compensation comes into effect.
70
®
MG.33.Q1.02 - VLT
is a registered Danfoss trademark
Syncronising Controller MCO 350 Operating
Instructions

Hide quick links: