Danfoss MCO 350 Operating Instructions Manual page 84

Syncronising controller
Table of Contents

Advertisement

5. Appendix
Error 152
Too many return
There are either more RETURN than corre-
sponding GOSUB commands in the program,
or there is a direct jump from a subroutine
with a GOTO command.
Only one RETURN is allowed per subprogram.
It is always better to jump to the beginning of
a subprogram and then to jump with IF... to a
previously defined label.
Error 154
D. out overload
5
Digital output overloaded.
Error 155
LINK failed
LINKGPAR command failed.
Error 162
Memory error
After saving something in the EEPROM (a pro-
gram or parameters) an error was detected
during verification.
Delete the EEPROM with a 3-finger reset and
try to save the program or parameters again.
If this is not successful please call the techni-
cal service department.
Error 170
Array sise (DIM)
The definition of an array in a DIM command
does not correspond to an already existing ar-
ray in the MCO 350.
Cause might be that the fields are from older
SYNCPOS/APOSS programs. The current pro-
gram has other definitions.
Either adapt the APOSS program to the cor-
rect array sise or delete the old arrays.
Error 171
Array too small
An attempt was made to describe an array el-
ement that is located outside of the defined
array limits.
Cause might be an error in the APOSS pro-
gram. Array sising does not agree with the
space required (e.g. due to an incorrectly pro-
grammed loop).
84
NB!
Remember to follow the recom-
mendations concerning saving
programs and parameters be-
fore deleting the EEPROM.
MG.33.Q1.02 - VLT
Syncronising Controller MCO 350 Operating
Or the array is too small for the number of test
drives triggered by TESTSTART.
Check loop variables.
Error 179
Waitndx timeout
The command WAITNDX was executed and
the timeout listed was exceeded.
The timeout is probably too short or the index
impulse could not found (see also Error 109).
Error 184
Too many ontime
Too many interrupts (ON TIME or ON PERIOD
commands) were used within the program.
A maximum of 12 of these ON TIME and/or
ON PERIOD commands are allowed within one
program.
Error 187
Out of memory
No more space for variables.
When the APOSS program is started the space
for the necessary variables is reserved dy-
namically. This space is now no longer avail-
able.
You may have selected a maximum number of
variables which is too high. Reduce the maxi-
Settings
mum number in
ard = 92).
Or the memory available is occupied with pro-
grams or arrays. Delete the programs or de-
lete both the programs and arrays, i.e. by
deleting the entire memory.
NB!
Remember to follow the recom-
mendations concerning saving
programs and parameters be-
fore deleting the EEPROM.
Error 190
Memory locked
The program memory is write-protected and
cannot be altered.
This means that auto recognition can neither
be set nor deleted and programs can neither
be saved nor deleted. Equally, →
EEPROM delete
and →
Error 191
Illegal cam array
An incorrect or old array is defined in the DIM
instruction for SETCURVE.
®
is a registered Danfoss trademark
Instructions
Compiler
(Stand-
RAM
save
will not be executed.

Hide quick links:

Advertisement

Table of Contents
loading