Monitor
Displays the input terminal status.
U1-10 = 0 0 0 0 0 0 0 0
U1-10
Displays the output terminal status.
U1-11 = 0 0 0 0 0 0 0 0
U1-11
Verifies the drive operation status.
U1-12 = 0 0 0 0 0 0 0 0
U1-12
U1-13
Terminal A1 Input Voltage
U1-14
Terminal A2 Input Voltage
U1-16
Output Speed after Soft Starter
U1-18
oPE Fault Parameter
Displays the contents of a MEMOBUS/Modbus error.
U1-19 = 0 0 0 0 0 0 0 0
U1-19
U2-01
Current Fault
U2-02
Previous Fault
U2-03
Speed Reference at Previous Fault
U2-04
Output Speed at Previous Fault
U2-05
Output Current at Previous Fault
U2-06
Motor Speed at Previous Fault
U2-07
Output Voltage at Previous Fault
U2-08
DC Bus Voltage at Previous Fault
U2-09
Output Power at Previous Fault
YASKAWA ELECTRIC TOEP C710616 33G AC Drive L1000A - Quick Start Guide
Description
1
Digital input 1
(terminal S1 enabled)
1
Digital input 2
(terminal S2 enabled)
1
Digital input 3
(terminal S3 enabled)
1
Digital input 4
(terminal S4 enabled)
1
Digital input 5
(terminal S5 enabled)
1
Digital input 6
(terminal S6 enabled)
1
Digital input 7
(terminal S7 enabled)
1
Digital input 8
(terminal S8 enabled)
1
Multi-Function
Digital Output
(terminal M1-M2)
1
Multi-Function
Digital Output
(terminal M3-M4)
1
Multi-Function
Digital Output
(terminal M5-M6)
1
Multi-Function
Digital Output
(terminal P1-C1)
1
Multi-Function
Digital Output
(terminal P2-C2)
Not Used
1
Fault Relay
(terminal MA-MC closed
MA-MC open)
1
During run
1
During zero-speed
1
Down Direction
1
Fault reset
signal input
1
During speed agree
1
Drive ready
1
During alarm
detection
1
During fault detection
1
CRC Error
1
Data Length Error
0
Not Used
1
Parity Error
1
Overrun Error
1
Framing Error
0
Timed Out
1
Not Used
Fault Trace
Monitor
U2-10
Torque Reference at Previous Fault
U2-11
Input Terminal Status at Previous Fault
U2-12
Output Terminal Status at Previous Fault
U2-13
Drive Operation Status at Previous Fault
U2-14
Cumulative Operation Time at Previous Fault
U2-15
Soft Starter Output at Previous Fault
U2-16
Motor q-Axis Current at Previous Fault
U2-17
Motor d-Axis Current at Previous Fault
U2-20
Heatsink Temperature at Previous Fault
Fault History
U3-01 to
First to 4th Most Recent Fault
U3-04
U3-05 to
5th to 10th Most Recent Fault
U3-10
Cumulative Operation Time at 1st to 4th Most Recent
U3-11 to
U3-14
Fault
Cumulative Operation Time at 5th to 10th Most Recent
U3-15 to
U3-20
Fault
Note:
The following faults are not recorded in the error log:
CPF00, CPF01, CPF02, CPF03, Uv1, and Uv2.
Fault Trace
U4-01
Cumulative Operation time
U4-24
Number of travels (lower 4 digits)
U4-25
Number of travels (upper 4 digits)
U4-26
Maximum Current during Acceleration
U4-27
Maximum Current during Deceleration
U4-28
Maximum Current during Constant Speed
U4-29
Maximum Current during Leveling Speed
DI/DO Sel.
Digital Input Function Selections
3
Multi-step speed reference 1
4
Multi-step speed reference 2
5
Multi-step speed reference 3
F
Not used (through mode)
14
Fault reset (Reset when turned ON)
External fault; Input mode: N.O. contact / N.C. contact
20 to 2F
Detection mode: Normal/during operation
50
Nominal speed (d1-19)
51
Intermediate speed
52
Releveling speed (d1-23)
53
Leveling speed (d1-26)
54
Inspection operation
56
Motor contactor feedback
79
Brake feedback
Digital Output Function Selections
During Run (ON: Run command is ON or voltage is being
0
output)
6
Drive Ready
E
Fault
F
Not used (through mode)
50
Brake Control
51
Output Contactor Control
58
Safe Disable Status
7 Parameter Table
Description
Description
EN 41