5 Start Up
Leveling Speed Priority is Selected and the Nominal Speed Input is Not Assigned (d1-18 = 2, H1- 50)
The drive runs at nominal speed (d1-19) when no speed selection input is set. When the leveling speed signal is set, the
drive decelerates to the leveling speed. The leveling speed signal has priority over all other speed signals.
CAUTION! This sequence can be risky if the speed selection doesn't work for some reason (broken wire, etc.)
I/O Signal Setup
Note:
The default setting functions can be seen in the connection diagram on page 12.
Multi-Function Digital Inputs
Assign functions to each digital input terminal using the H1- parameters.
Multi-Function Digital Outputs
Determine the function for each digital output terminal with the H2- parameters. The setting value of these
parameters consists of three digits, where the middle and right digit determines the function, and the left digit sets the
output characteristics. The output characteristics can be either "Output as selected" (0) or "Inverse output" (1).
Multi-Function Analog Inputs
The function of each analog input can be assigned in the H3- parameters.
Multi-Function Analog Outputs
Use the H4- parameters to set up the output value of the analog monitor outputs and to adjust the output signal
levels.
Acceleration Ramp, Deceleration Ramp, and Jerk Settings
The acceleration and deceleration ramps are set in the parameters C1-01 and C1-02, while the jerk settings are set in the
C2- parameters as shown in the figure below.
Jerk Characteristic
C2-01
Jerk Characteristic
at Accel Start
The way of setting these parameters and their setting units change with parameter o1-03 as shown below:
Accel/Decel Ramps C1-

Jerk Settings C2-

EN 32
DC Injection/
position lock
Speed
Safe disable
Up/Down
Leveling speed
C2-02
at Accel End
Acceleration Ramp 1
C1-01
Deceleration Ramp 1
C1-02
o1-03 = 0, 1, 2, 3, 4
Set in units of second as the time to accelerate from
zero to the rated speed, respectively as time to
decelerate from rated speed to zero.
Set in units of second as the time used to change the
accel/decel ramp from zero to the accel/decel ramp
setting of C1- and vice versa.
DC Injection/
position lock
C2-03
Jerk Characteristic
at Decel Start
C2-04
Jerk Characteristic
C2-05 Jerk below Leveling Speed
at Decel End
Leveling Speed
Set in units of m/s
changing the speed.
Set in units of m/s
YASKAWA ELECTRIC TOEP C710616 33G AC Drive L1000A - Quick Start Guide
Input is set
o1-03 = 5
as accel/decel ramp used when
2
3
as the accel/decel change rate.