3 Electrical Installation
Type
No.
+V
Power supply for analog inputs
Power supply for analog inputs
–V
A1
Multi-function analog input 1 (Speed Reference Bias) -10 to 10 Vdc, 0 to 10 Vdc (input impedance: 20 k)
Analog Inputs
Multi-function analog input 2 (Not used)
A2
Analog Input common
AC
E (G) Ground for shielded lines and option cards
MA N.O. output
MB N.C. output
Fault Relay
MC Fault output common
M1
Relay output 1 (Brake Control)
M2
Multi-Function
M3
Relay output 2 (Output Contactor Control)
Relay Output
M4
M5
Relay output 3 (Drive Ready)
M6
P1
Photocoupler output 1 (During frequency output 2)
Multi-Function
C1
Photocoupler
P2
Output
Photocoupler output 2 (Not used)
C2
Analog monitor output 1 (Output speed)
FM
Monitor Output
AM Analog monitor output 2 (Output current)
Monitor common
AC
DM+ Safety monitor output
Safety Monitor
Output
DM– Safety monitor output common
NOTICE: The terminals HC, H1, H2 are used for the Safe Disable function. Safe Disable can be used to enable/disable the drive. If
special requirement are fulfilled, it can also be utilized for reducing the number of motor contactors to one. Refer to
Function on page 48
for details. Always remove the wire link between HC, H1, or H2 when using Safe Disable.
NOTICE: The wiring length to terminals HC, H1 and H2 should not exceed 30 m.
NOTICE: When connecting a reactive load such as a relay coil to a photo coupler output, attach a flywheel diode to the load (relay coil)
like shown below. Ensure the diode rating is greater than the circuit voltage.
EN 18
Terminal Name (Function)
DC Power
Supply (max 48 V)
Function (Signal Level) Default Setting
10.5 Vdc (max. allowable current 20 mA)
-10.5 Vdc (max. allowable current 20 mA)
-10 to 10 Vdc, 0 to 10 Vdc (input impedance: 20 k)
0 V
30 Vdc, 10 mA to 1 A; 250 Vac, 10 mA to 1 A
Minimum load: 5 Vdc, 10 mA
Photocoupler output 48 Vdc, 2 to 50 mA
-10 to +10 Vdc, 0 to +10 Vdc
0 V
Outputs status of Safe Disable function. Closed when both Safe
Disable channels are closed. Up to +48 Vdc 50 mA.
Flywheel diode
Reactive
I (max 50 mA)
load
YASKAWA ELECTRIC TOEP C710616 33G AC Drive L1000A - Quick Start Guide
Safe Disable Input

Advertisement