YASKAWA L1000A Quick Start Manual page 39

Ac drive for elevator applications
Hide thumbs Also See for L1000A:
Table of Contents

Advertisement

No.
Name
Sets the signal level for terminals FM and
H4-02,
Terminal FM,
AM that are equal to 100% of the monitor
H4-05
AM Gain
output that has been selected.
Sets the signal level for terminals FM and
H4-03,
Terminal FM,
AM that are equal to 0% of the monitor
H4-06
AM Bias
value.
0: 0 to 10 V
H4-07,
Terminal FM,
H4-08
AM Signal Sel.
1: -10 to 10 V
Motor Protection
0: Disabled
1: General purpose motor (self-
Motor
cooled)
Overload
L1-01
2: Drive dedicated motor with a speed range
Protection
of 1:10
Selection
3: Vector motor with a speed range of 1:100
5: PM motor with constant torque control
Inertia Compensation Control
Inertia
0: Disabled
n5-01
Compensation
1: Enabled
Selection
Motor
Sets the time the motor needs to accelerate
n5-02
Acceleration
from 0 to the nominal speed at 100% torque.
Time
Inertia
Sets the gain used for inertia compensation.
n5-03
Compensation
This value defines the ratio between motor
Control Gain
and load inertia.
Digital Operator Display Selection
0: 0.01 Hz
1: 0.01%
2: r/min
Digital
4: Elevator units 1 (speed = m/s, accel/decel
Operator
o1-03
ramp = s, Jerk = s)
Display Unit
5: Elevator units 2 (speed = m/s, accel/decel
Selection
ramp = m/s
Note:
o1-20, o1-21, and o1-22 must also be set.
Traction
o1-20
Sheave
Set the traction sheave diameter in mm.
Diameter
1: 1:1
2: 1:2
o1-21
Roping Ratio
3: 1:3
4: 1:4
o1-22
Gear Ratio
Set the gear ratio of the mechanical gear.
Brake Sequence
Zero Speed
S1-01
Sets the speed to close the brake at stop.
Level at Stop
DC Injection
S1-02
Current at Start Adjusts the torque to hold the motor at zero
speed during start and stop.
DC Injection
Increase if roll-back occurs.
S1-03
Current at Stop
DC Inj./
Sets the time between the Up/Down
S1-04
Position Lock
command and acceleration start.
Time at Start
DC Inj./
Sets the time between reaching the Zero
S1-05
Position Lock
Speed Level and when the drive output
Time at Stop
shuts off.
Brake Release
Sets the wait time between the Up/Down
S1-06
Delay Time
command and the brake release command.
YASKAWA ELECTRIC TOEP C710616 33G AC Drive L1000A - Quick Start Guide
Description
2
, Jerk = m/s
3
)
If o1-03 = 4 or 5, then parameters
No.
Name
Brake Close
Sets the wait time between reaching Zero
S1-07
Delay Time
Speed and the brake close command.
Motor
Sets the state of the output contactor control
Contactor
S1-12
command (H2- = 51) during Auto-
Control during
Tuning.
Auto-Tuning