Filtering Tips - Broaster 1600 Operation Manual

Pressure fryer w/smart touch control
Hide thumbs Also See for 1600:
Table of Contents

Advertisement

FILTERING TIPS

COMPLAINT
Motor will not start
Turn power switch to OFF
position to avoid splash-
ing of oil when motor pro-
tector reset button is
pushed.
Motor hums but will not
start
Motor starts but will not
pump
Motor starts but will not
pump or stops at any level
Motor starts but stops
pumping when oil is level
with top of hold down,
approximately 1 inch of oil
in bottom
CAUSE
1. Overload tripped
2. Open or faulty wall fuse
or circuit breaker
1. Solidified shortening in
pump
2. Crumbs in pump
1. Filter pan not completely
installed
2. O-ring on riser line not
installed
3. Solidified shortening in
piping or filter pan
1. Filter paper or hold down
improperly installed
2. Not using enough
®
Broaster
filtering com-
pound
1. Filter paper improperly
installed or crumbs under
filter paper or hold down
11-6
broaster.com Manual #17269 8/13 Rev 5/14
REMEDY
1. Wait for overload to cool.
Push red motor protector
reset button located on
rear of motor.
2. Check wall fuse or circuit
breaker
1. Turn cook/filter switch
OFF. Contact service
person.
2. Turn cook/filter switch
OFF. Contact service
person.
1. Firmly push filter pan in
2. See FILTERING
3. Turn cook/filter switch
OFF. Contact service
person.
1. See COOKING OIL CARE
AND FILTERING
2. Next filtering cycle, make
sure proper amount of
®
Broaster
filtering com-
pound is used
1. See COOKING OIL CARE
AND FILTERING

Advertisement

Table of Contents
loading

This manual is also suitable for:

1800

Table of Contents