3.14 Fail safe

There are two possibilities for use if the transmitter signal is under abnormal
condition,the first one is lock the last action date received; the second one is to
execute the pre-set date which is pre-set. The default setting is Servo Hold
setting method:
Press ENT to enter flash main menu. Press UP or DN until FUNCTION flash,repress
ENT flash to enter function menu; press UP or DN until SAFE flash ;press ENT to FAIL
SATE setting interface. There are ELEV,AILE,THRO,RUDD,GEAR,PITCH,GYRO 7
channel setting. Take the item Elevator as an example to explain.
On above interface,press R or L to selet keep or fail safe. If selecting keeping,locking
the last dated received; If selecting fail safe, to execute the pre-set date which is
pre-set. The default setting is Servo Hold
Press R to SAFE,press DN to enter fail safe date interface