Rudder
R62.5%-L62.5%
EXT it for finish.

3.4 Dual rate and exponential

It is possible to use D/R switch to control over the dual rate of elevator, aileron, and
rudder,after the function of Dual Rate and Exponential is setup. The setting range is
0-125%. Under the help with exponential curve adjustment, it is not only manually but
also automatically able to set up various parameters which are suitable for yourself.
Under working with Flight Mode, it is possible to switch between the dual rate and
exponential.
1) Channel selection
Setting method: Press ENT to enter Main Menu. Press UP or DN to flash
"FUNCTION", and then press ENT to enter Function menu; Press UP or DN until
"DREXP" blink; Press ENT to enter the options for Channel names. Press R or L,
there is a selectable list for ELEV, AILE, RUDD. Here we take the ELEV for example.
The picture as below:
2) Position selection
Press DN to enter Switch Position setting in the above Picture, there are
POS0,POS2,POS3. Press R or L, it is possible to choose POS0,POS1,POS2,POS3.
The D/P Switch Position on transmitter
DEVO-7