B.4 MEMORY MAPPING
Table B–10: MODBUS MEMORY MAP (Sheet 38 of 63)
ADDR
REGISTER NAME
7F6A
Reserved (7 items)
Auxiliary Overvoltage (Read/Write Grouped Setting)
7FA0
Auxiliary Overvoltage 1 Function
7FA1
Auxiliary Overvoltage 1 Signal Source
7FA2
Auxiliary Overvoltage 1 Pickup
B
7FA3
Auxiliary Overvoltage 1 Pickup Delay
7FA4
Auxiliary Overvoltage 1 Reset Delay
7FA5
Auxiliary Overvoltage 1 Block
7FA7
Auxiliary Overvoltage 1 Target
7FA8
Auxiliary Overvoltage 1 Events
7FA9
Reserved (8 items)
Frequency (Read Only)
8000
Tracking Frequency
Temp Monitor Actual Values (Read Only Non-Volatile)
81C0
Reserved Register T1
81C1
Reserved Register T2
81C2
Reserved Register T3
81C4
Reserved Register T4
81C6
Reserved Register T5
81C8
Reserved Register T6
81CA
Reserved Register T7
81CC
Reserved Register T8
Breaker Failure (Read/Write Grouped Setting) (2 modules)
8600
Breaker Failure 1 Function
8601
Breaker Failure 1 Mode
8602
Breaker Failure 1 Source
8603
Breaker Failure 1 Amp Supervision
8604
Breaker Failure 1 Use Seal-In
8605
Breaker Failure 1 Three Pole Initiate
8607
Breaker Failure 1 Block
8609
Breaker Failure 1 Phase Amp Supv Pickup
860A
Breaker Failure 1 Neutral Amp Supv Pickup
860B
Breaker Failure 1 Use Timer 1
860C
Breaker Failure 1 Timer 1 Pickup
860D
Breaker Failure 1 Use Timer 2
860E
Breaker Failure 1 Timer 2 Pickup
860F
Breaker Failure 1 Use Timer 3
8610
Breaker Failure 1 Timer 3 Pickup
8611
Breaker Failure 1 Breaker Status 1 Phase A/3P
8613
Breaker Failure 1 Breaker Status 2 Phase A/3P
8615
Breaker Failure 1 Breaker Test On
8617
Breaker Failure 1 Phase Amp Hiset Pickup
8618
Breaker Failure 1 Neutral Amp Hiset Pickup
8619
Breaker Failure 1 Phase Amp Loset Pickup
861A
Breaker Failure 1 Neutral Amp Loset Pickup
861B
Breaker Failure 1 Loset Time
861C
Breaker Failure 1 Trip Dropout Delay
861D
Breaker Failure 1 Target
861E
Breaker Failure 1 Events
861F
Breaker Failure 1 Phase A Initiate
8621
Breaker Failure 1 Phase B Initiate
8623
Breaker Failure 1 Phase C Initiate
8625
Breaker Failure 1 Breaker Status 1 Phase B
B-46
RANGE
0 to 65535
0 to 1
0 to 5
0 to 3
0 to 600
0 to 600
0 to 4294967295
0 to 2
0 to 1
0 to 65535
2 to 90
-55 to 125
-55 to 125
-2147483647 to
2147483647
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 1
0 to 1
0 to 5
0 to 1
0 to 1
0 to 4294967295
0 to 4294967295
0.001 to 30
0.001 to 30
0 to 1
0 to 65.535
0 to 1
0 to 65.535
0 to 1
0 to 65.535
0 to 4294967295
0 to 4294967295
0 to 4294967295
0.001 to 30
0.001 to 30
0.001 to 30
0.001 to 30
0 to 65.535
0 to 65.535
0 to 2
0 to 1
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
L30 Line Current Differential System
APPENDIX B
UNITS
STEP
FORMAT
---
1
F001
---
1
F102
---
1
F167
pu
0.001
F001
s
0.01
F001
s
0.01
F001
---
1
F300
---
1
F109
---
1
F102
---
1
F001
Hz
0.01
F001
C
1
F002
C
1
F002
---
1
F004
---
1
F003
---
1
F003
---
1
F003
---
1
F003
---
1
F003
---
1
F102
---
1
F157
---
1
F167
---
1
F126
---
1
F126
---
1
F300
---
1
F300
pu
0.001
F001
pu
0.001
F001
---
1
F126
s
0.001
F001
---
1
F126
s
0.001
F001
---
1
F126
s
0.001
F001
---
1
F300
---
1
F300
---
1
F300
pu
0.001
F001
pu
0.001
F001
pu
0.001
F001
pu
0.001
F001
s
0.001
F001
s
0.001
F001
---
1
F109
---
1
F102
---
1
F300
---
1
F300
---
1
F300
---
1
F300
DEFAULT
0
0 (Disabled)
0 (SRC 1)
300
100
100
0
0 (Self-reset)
0 (Disabled)
0
0
-55
125
0
0
0
0
0
0
0 (Disabled)
0 (3-Pole)
0 (SRC 1)
1 (Yes)
1 (Yes)
0
0
1050
1050
1 (Yes)
0
1 (Yes)
0
1 (Yes)
0
0
0
0
1050
1050
1050
1050
0
0
0 (Self-reset)
0 (Disabled)
0
0
0
0