Download Print this page

Exiting Man Down Feature; Re-Initiating Man Down; Testing The Man Down Feature - Motorola 3 User Manual

Apx two-way radios apx 1000+
Hide thumbs Also See for 3:

Advertisement

English
Once the alert tone is active, changing to another channel
with different setup triggers a different response from the
radio as described next.
The alert tone is inhibited when you change to a
channel without Emergency feature.
The alert tone is inhibited when you change to a
channel with Emergency but no Man Down feature.
The current alert tone is inhibited and is replaced with a
different alert tone when you change to a channel with
Emergency and different Man Down configuration.
The alert tone continues when you change to a channel
with Emergency and similar Man Down configuration.

Exiting Man Down Feature

If you are not in a real Man Down situation, you should exit
the Man Down feature and prevent emergency from going
off with the following operation.
Perform one of the following actions:
Repositioning the radio or shaking the radio
(when motion sensitivity is enabled).
Press the preprogrammed Man Down Clear
button to exit.
112
Press the Menu Select button below Clr to exit.

Re-Initiating Man Down

After exiting the Emergency Operation when the radio is
still in Man Down condition (tilted achieving threshold angle
or motionless), user must first exit Man Down condition to
then reinitiate the Man Down feature.
Return the radio to the vertical position or shake the
radio (when motion sensitivity is enabled).

Testing the Man Down Feature

Enable the Emergency feature with Silent Alarm disabled,
but not in Surveillance Mode before running this test on the
radio.
1 Turn the radio on and place in the vertical position,
for at least 5 seconds.
2 Lay the radio down in the horizontal position.
3 Wait for alert tone.
One of the following scenarios occurs:
Send Feedback