MODULAR SAFETY INTEGRATED CONTROLLER MOSAIC
Manual reset: If selected this enables the request to reset each time the safety pedal is
activated. Otherwise, enabling of the output directly follows the input conditions.
There are two types of reset: Manual and Monitored. When Manual is selected the system
only verifies the signal's transition from 0 to 1. If Monitored is selected the double
transition from 0 to 1 and then back to 0 is verified.
t = 250ms
WARNING: If the Manual Reset is active, a consecutive Input have to be used.
Example : Input 1 and Input 2 are used for the fuctional block, then Input 3 have to
be used for the Reset Input.
Output test: This is used to select which test output signals are to be sent to the
component contacts. This additional control permits detection and management of any
short-circuits between the lines. To enable this control, the test output signals must be
configured (amongst those available).
Test at start-up: If selected this enables the test at start-up of the external component.
This test is performed by pressing and releasing the footswitch to run a complete
function test and enable the output. This test is only requested at machine start-up
(when the unit is switched on).
Filter (ms): This is used to filter the signals coming from the external contacts. The filter
can be configured to between 3 and 250 ms and eliminates any bouncing on the
contacts. The length of the filter affects the calculation of the unit's total response time.
With Simultaneity: If selected this activates the test to verify concurrent switching of the
signals coming from the external contacts.
Simultaneity (ms): This is only active if the previous parameter is enabled. It defines the
maximum time (in msecs) between the switching of two different signals from the
external contacts.
Enable Error Out: If selected reports a fault detected by the function block.
Item description: This allows a description of the component's function to be entered. The
text is displayed in the top part of the symbol.