Zero speed limit:
Enter in this field the maximum speed value above which the
output of the function block (ZERO) will be 0 (FALSE). If the
measured speed is less than the set value, the output (ZERO)
of the function block will be 1 (TRUE).
Frequency zero speed: It shows the maximum calculated
frequency values fM and fm (decreased by the hysteresis set).
If the displayed value is GREEN, the calculation of frequency
gave a positive result.
If the displayed value is RED, it is necessary to change the
parameters given in the following formulas.
1. Rotary axis, rotary sensor. The frequency obtained is:
rpm
[rev/m in]
f
[Hz]
60
2. Linear axis, rotary sensor. The frequency obtained is:
speed
[m/min]
f
[Hz]
60
*
pitch
[mm/rev]
3. Linear axis, linear sensor. The frequency obtained is:
speed
[m m /s]
f
[Hz]
Re
solution
4. Hysteresis. To be changed only if: fM=green; fm=red
112
Re
solution
[pulses/re
v]
*
1000
Re
solution
[pulses/re
*
1000
[µm /pulse]
MODULAR SAFETY INTEGRATED CONTROLLER MOSAIC
KEY:
f = frequency
Rpm = rotational speed
Resolution = measurement
Speed = linear speed
Pitch = sensor pitch
v]
8540780 • 23/03/2017 • Rev.31