The expansion units in the MB series permit connection to the most commonly
used industrial fieldbus systems for diagnostics and data transmission.
The MBEI, MBEI2B, MBEP, MBEM and MBEC also have an ethernet connection. The
MBU permits connection to devices with a USB port.
The MCT1 and MCT2 Mosaic units are used to connect the M1 to other slave
units installed at a distance (< 50 m). Two MCT units installed at the required
distance can be connected using a shielded cable (ReeR MC25, MC50 or other
cable with the characteristics set out in the cable data sheet).
The MV0, MV1 and MV2 Mosaic expansion units can be used to control the
following (up to PLe):
 Zero speed, Max. speed, Speed range;
 Direction of movement, rotation/translation;
Up to 4 speed thresholds can be set for each logic output (axis).
Each unit incorporates two logic outputs that can be configured using the MSD
software and is thus capable of controlling up to two independent axes.
The MOR4 and MOR4S8 are safety units provided with 4 independent safety relay
outputs and the corresponding 4 inputs for the external feedback contacts (EDM).
There are two possible output settings (configured using the MSD configuration
software).
 Two pairs of connection contacts (2 N.O. contacts per output with 2
corresponding feedback inputs).
 Four independent single connection contacts (1 N.O. contact per output
with 1 corresponding feedback input).
Only the MOR4S8 unit has 8 programmable signal outputs.
The MOS8 and MOS16 have 8 and 16 programmable signal outputs.
The MSD software is capable of creating complex logics, using logical operators
and safety functions such as muting, timer, counters, etc.
All this is performed through an easy and intuitive graphic interface.
The configuration performed on the PC is sent to the M1 via USB connection; the
file resides in the M1 and can also be saved on the proprietary MCM memory chip
(accessory). The configuration can therefore quickly be copied to another M1 unit.
The MOSAIC system is certified to the maximum safety level envisaged by the
applicable industrial safety standards (SIL 3, SILCL 3, PL e, Cat. 4).