3.2.4 Inverter Board and Lamp Unit Removal

Inverter Board
Step 1:
Remove the upper case (Refer to section 3.2.2.)
Step 2:
Disconnect the FFC cable from the inverter board.
Step 3:
Remove the three white CB (M3 x 6) screws that fastens on the inverter board then remove
the inverter board.
Lamp Unit
Step 1:
Remove the inverter board (Refer to above.).
Step 2:
Remove the black screw that fastens the lamp unit and the inverter board.
Step 3:
Disconnect the lamp unit which is fixed by two connectors to the inverter board.
Rev. A
FFC Cable
Figure 3-5. Inverter Board and Lamp Unit Removal
Lamp Unit
Figure 3-6. Lamp Unit Removal
DISASSEMBLY AND ASSEMBLY
Inverter Board
Inverter
Board
3-7