4.2.3.6 Lamp Assembly and Inverter Board Assembly Removal

This section describes how to remove the lamp assembly and the inverter
board assembly from the carriage.
1. Remove the glass frame assembly. (See Section 4.2.3.5.)
2. Move the CR to the position indicated in Figure 4-19. (The position
where the front and rear frames are indented.)
3. Remove 2 screws (No.6) securing the carriage mirror cover and slide
the cover toward the rear side of the scanner to release the
engagement with the hook on the carriage. Then lift up the cover and
remove it.
<Continued to the following page.>
Rev. A
Disassembly and Assembly
Screws (No.6)
Figure 4-18. CR Mirror Cover Removal