Step
Cause
1
CN1 on the power
supply unit is
disconnected.
2
CN2 on the power
supply unit is
disconnected.
3
The fuse on the power
supply unit is burnt.
4
The power supply unit
is defective.
5
CN5 on the digital
board unit is
disconnected.
6
CN on the LED board
is disconnected.
7
CN6 on the digital
board unit is
disconnected.
8
The digital board unit is
defective.
Step
Cause
1
The digital board unit is
defective.
5-4
OPERATE LED does not light
Table 5-5.
Check Point
Is CN1 on the power supply unit
disconnected?
Is CN2 on the power supply unit
disconnected?
Is the fuse on the power supply
unit burnt?
Detach CN2 on the power
supply unit.
Check the CN2 is outputting the
following voltages:
(+): Pin 8 of CN3
(-): Pin 5 of CN3
Is the output voltage +5 VDC?
Is CN5 on the digital board unit
disconnected?
Is CN on the LED board
disconnected?
Is CN on the LED board
disconnected?
The scanner does not begin initialisation
Table 5-6.
Check Point
Decision
Yes
Yes
Yes
No
Yes
Yes
Yes
--
Decision
--
Solution
Connect CN1 on the
power supply unit.
Connect CN2 on the
power supply unit.
Replace the fuse.
Replace the power
supply board.
Connect CN5 on the
digital board unit.
Connect CN on the LED
board.
Connect CN on the LED
board.
--
Replace the digital board
unit.
Solution
--
Replace the digital board
unit.