Teledyne G3-GM10-M0641 User Manual page 116

Genie nano series; genie nano xl series gige vision camera m640 series; m640 nir series; m800 series; m800 nir series; m1240 series; m1280 series; m1280 nir series; m1450 series; m1930 series; m1930 nir series; m1940 series; m1920 series; m2050 series; m2
Table of Contents

Advertisement

TriggerOverlap=ReadOut
Trigger is accepted at the beginning of the frame Readout. The "End of Exposure to Start of
Readout" time is sensor dependent.
Diagram Conditions:
TriggerMode=On
ExposureMode=Timed
TriggerActivation=RisingEdge
TriggerDelay=0
TriggerSelector=FrameStart
ExposureAlignment=Synchronous
TriggerOverlap=Readout
Trigger Input
Frame Exposure
Frame Readout
Timing specific to OnSemi models
Trigger to Exposure start has a delay which includes the sensor readout time plus a
minimum of 62µs. An exposure always starts after the readout of the previous frame.
Trigger Delay Times (min. with normal ROT):
M/C2590: 23318µs
M/C1930: 10907µs
M/C1280: 5751µs
M/C800: 2407µs
M/C640: 1677µs
114
Operational Reference
Trigger Exclusion Period
Exposure 1
End of Exposure
to Start of Readout
Frame 1 Active period
Trigger Exclusion Period
Exposure 2
End of Exposure
to Start of Readout
Readout 1
Frame 2 Active period
Nano Series GigE Vision Camera
Readout 2

Hide quick links: