Noise Test Results - Fluke DSP-4100 User Manual

Cableanalyzer dsp-4000 series
Hide thumbs Also See for DSP-4100:
Table of Contents

Advertisement

Noise Test Results

As the noise test runs, the displayed test results are updated every second after the
first 10-second sample period. Table 4-6 describes the items on the screen.
Item
Impulse
Noise
Threshold
Noise Test
Average
Peak
$
Stop
Test
Table 4-6. Items on the Noise Monitor Screen
The minimum level of noise that is considered to be a noise hit. The
default threshold is 270 mV. If you want to change the fault threshold, see
the earlier section "Changing the Impulse Noise Threshold."
The overall result of the noise test. Displayed only when 10BASE-T is
selected. A PASS result means that no 10-second intervals included more
than two noise hits. A FAIL result means that more than two noise hits
were detected during a 10-second interval.
The average number of noise hits per second since the start of the test.
The highest number of noise hits per second and the time at which the
peak was recorded.
Stops the noise test and freezes the screen. To restart the noise test,
press T.
Running Individual Tests
Monitoring Impulse Noise