The Autotest Report - Fluke DSP-4100 User Manual

Cableanalyzer dsp-4000 series
Hide thumbs Also See for DSP-4100:
Table of Contents

Advertisement

DSP-4000 Series
Users Manual

The Autotest Report

With LinkWare software you can upload reports to a PC for viewing and printing.
Figures 3-12 and 3-13 show examples of reports generated with LinkWare
software.
You can send Autotest reports directly to a serial printer or edit the report's
identification information in the PRINT mode. See Chapter 5, "Viewing and
Printing Saved Reports," for complete instructions.
The overall result printed on a report can be a pass or fail, or warning. A failure of
any test required by the selected test standard produces a fail result on the report
summary. If required by the selected standard, a warning appears on reports for
twisted pair cabling if a length, impedance, propagation delay, or delay skew test
produced a warning. The warning means that the measurement exceeds its limit,
but the test standard does not fail the cabling based on that measurement.
3-32