SECTION 5 − POWER SOURCE/SYSTEM SETUP

5-1. Coolant Hose Connections To Single Output Cable

Single Liquid−Cooled
Output Connection
1
2
3
1
Power Source/Cooler Assembly
2
Rolling Inductor Output Cable
3
Protective Cap
4
Coolant Hose
5
Heavy Duty Induction Cooler
Connect output cable to output #1 on power
source. Connect protective plug to power
source output #2.

5-2. Coolant Hose Connections To Dual Output Cables

Dual Liquid−Cooled
Output Connection
2
2
3
.
Workpieces should be the same size
and material when connecting two
Rolling Inductors to one power source.
1
Power Source/Cooler Assembly
2
Rolling Inductor Output Cable
3
Coolant Hose
4
Dual Output Cable Coolant Hose
5
Heavy Duty Induction Cooler
Connect output cables to output #1 and
OM-261823 Page 10
2
3
2
To
Cooler
4
4
Connect quick-connect fitting on both
coolant hoses from cooler to output cable
fittings by pushing coolant hose fitting onto
output cable fitting.
.
Stop coolant flow before connecting/
disconnecting coolant hoses.
1
2
3
2
To
2
Cooler
3
4
output #2 on power source.
Coolant hoses between output cables and
cooler must be connected in series for dual
output operation. Connect dual output
coolant hose between output cable #1 and
output cable #2 fittings by pushing coolant
hose fitting onto output cable fitting.
Connect quick-connect fitting on both
coolant hoses from cooler to remaining
output cable fittings.
1
5
804 435-A
To remove coolant hoses, grasp black ring
on coolant hose fitting and pull away from
output cable fitting . Coolant hose fitting will
separate from output cable fitting.
.
4
.
3
To remove coolant hoses, grasp black ring
on coolant hose fitting and pull away from
output cable fitting . Coolant hose fitting will
separate from output cable fitting.
.
Fittings have spring loaded valves
inside that close when fitting is discon-
nected from an output cable fitting to
minimize coolant leaks.
1
5
Stop coolant flow before connecting/
disconnecting coolant hoses.
Fittings have spring loaded valves
inside that close when fitting is discon-
nected from an output cable fitting to
minimize coolant leaks.