5-7. Mounting Travel Sensor Assembly To The Rolling Inductor

2

5-8. Mounting IR Assembly To The Rolling Inductor

OM-261823 Page 14
3
4
1
5
3
5
1
4
2
Ref. 262 417-A
1
Travel Sensor Assembly
2
Securing Knob
3
4-Pin Connector
4
Tension Adjustment Knob
5
Mounting Bracket
Slide travel sensor assembly onto the
mounting bracket on either side of the
Rolling Inductor. Tighten knob to secure as-
sembly in place.
Connect 4-pin end of supplied cable to the
travel sensor assembly 4-pin connector.
Connect 14-pin end of the cable to the
14-pin connector on back of power source.
Once installed on pipe, use the tension ad-
justment knob to ensure wheel is tight to
pipe. Wheel contact with pipe may loosen
during heating causing wheel to slip. Adjust
tension again at that point to ensure wheel
is rotating. Holes in side of wheel allow user
to visually monitor wheel rotation.
NOTICE −If power source does not have
the travel sensor lead installed internally on
the 14-pin connector (Pin G), kit #268031
must be installed by a qualified person in or-
der to use the travel sensor.
.
Power source software revision 1.21 or
lower must be updated in order to oper-
ate using this accessory.
NOTICE −Older Rolling Inductor units may
not have mounting bracket installed. Have
kit 262527 installed by a qualified person.
.
When using two Rolling Inductors, only
one Travel Detect System can be used.
1
IR Assembly
2
Mounting Rails
3
Securing Knob
4
5-Pin IR Connector
5
Air Hose Fitting
Slide IR assembly onto the mounting rail on the
front of the Rolling Inductor. Tighten knob to se-
cure assembly in desired location.
Connect 5-pin connector on the Rolling Induc-
tor side of the IR extension cable (see Section
5-6) to the 5-pin IR connector on the IR assem-
bly. Connect 5-pin connector on ProHeat side
of the cable to receptacle RC1 or RC2 on con-
nection box (see Section 6-8).
Connect air hose from air filter-regulator as-
sembly (see Section 5-11) to air-hose fitting on
IR assembly.
.
In order for this accessory to operate cor-
rectly, the software must be updated if the
current revision level for the Power Source
Micro board is lower than 1.25, or if the cur-
rent revision level for the Operator Inter-
face Micro board is less than 1.28. The cur-
rent software revision levels are shown on
the front panel display on the ProHeat 35
when it is first turned on. To update soft-
ware, contact Miller Service @ www.PW-
PService@MillerWelds.com.
Ref. 262 417-A

Advertisement

Table of Contents
loading

This manual is also suitable for:

301149301183

Table of Contents