Section 4 − Specifications; Serial Number And Rating Label Location; Software Licensing Agreement; Information About Default Weld Parameters And Settings - Miller Syncrowave 400 Owner's Manual

Table of Contents

Advertisement

4-1. Serial Number And Rating Label Location

The serial number and rating information for the power source is located on the rear of the machine. Use the rating labels to determine input power
requirements and/or rated output. For future reference, write serial number in space provided on back cover of this manual.

4-2. Software Licensing Agreement

The End User License Agreement and any third-party notices and terms and conditions pertaining to third-party software can be found at
https://www.millerwelds.com/eula

4-3. Information About Default Weld Parameters And Settings

NOTICE − Each welding application is unique. Although certain Miller Electric products are designed to determine and default to certain typical welding
parameters and settings based upon specific and relatively limited application variables input by the end user, such default settings are for reference
purposes only; and final weld results can be affected by other variables and application-specific circumstances. The appropriateness of all parameters
and settings should be evaluated and modified by the end user as necessary based upon application-specific requirements. The end user is solely
responsible for selection and coordination of appropriate equipment, adoption or adjustment of default weld parameters and settings, and ultimate
quality and durability of all resultant welds. Miller Electric expressly disclaims any and all implied warranties including any implied warranty of fitness
for a particular purpose.

4-4. Welding Power Source Specifications

.
This equipment will deliver rated output at an ambient air temperature up to 1045 F ( 405 C).
.
Do not use information in unit specifications table to determine electrical service requirements. See Sections 5-6, 5-7 and 5-8 for information on
connecting input power.
Welding Amperage Range
5-400*
*Welding range for Stick process is 5-300A amperes. For TIG, the amperage range is tungsten diameter dependent (see Sections 6-5) depend-
ing on model.
** Arc starting device is designed for manual guided operations.
*** Low open-circuit voltage while in TIG Lift Arct, or while in Stick with low open-circuit voltage selected.
Process
Current
(A)
300
250
STICK
200
400
TIG*
300
250
.
A complete Parts List is available at www.MillerWelds.com
SECTION 4 − SPECIFICATIONS
and are incorporated by reference herein.
Max Open Circuit Voltage (Uo)
70
Output Ratings
Duty
Voltage (V)
Cycle
32
30%
30
60%
28
100%
26
30%
22
60%
20
100%
Low Open-Circuit Voltage (Uo)
8-15***
Current Draw (A)
At Rated Input Voltages (V)
Phase
208V
240V
1
64 (20%)
54
3
34
30
47
1
43
(235A out)
3
27
24
35
1
32
(190A out)
3
20
18
1
77 (20%)
65
3
40
36
43
1
42
(280A out)
3
25
23
1
36
32
3
19
18
Rated Peak Striking Voltage
(Up)
14KV**
Input Power
480V
kW
kVA
26
12
13.1
15
11.8
12.3
21
9.5
10.4
12
9.4
9.8
15
7.1
7.7
9
7.0
7.4
31
14.2
15.4
17
13.8
14.5
20
8.9
9.7
11
8.8
9.1
15
6.7
7.4
9
6.6
6.9