When using two Rolling Inductors, Two IR sensors can be used at the same time.
.
Workpieces should be the same size and material when using two Rolling Inductors on one power source.
NOTICE −TC5 and TC6 connect to the Rolling Inductor internal thermocouple which monitors internal Rolling Inductor core temperatures.
Measure workpiece temperature with temperature crayons, infrared sensors, or contact thermocouples placed within two inches of the Rolling Induc-
tor.
Set Trvl Detect to On if using travel detection.
.
Must be set to Off if not using Trvl Detect, or unit will not activate heat output.
Travel detection is recommended for all Rolling Inductor applications. It assists in maintaining an even heat input to the part and regulates output
power based on travel speed in Temp mode.
Set Trvl Speed units as needed.
Press Program
button once to enter the Rolling Inductor Program screen.
.
If Manual Mode was selected the screen should look as shown below.
Mode....: Manual
Command.: >0.0 KW
Run Time: 00:03:00
Plug one end of the thermocouple extension cable into TC5 on the power source and the other end into the back of the Rolling Inductor.
If running two Rolling Inductors on the same power source, connect a second thermocouple extension cable from the second Rolling Inductor to
TC6 on the power source.
Notes
Rolling Inductor Program Screen
Frequency: 4.5 kHz
Power...: 0.0 KW
Current: 0 A
Voltage: 0 V