Current Output 1 To; Assign Current Output - Endress+Hauser Levelflex FMP55 Operating Instructions Manual

Guided wave radar
Hide thumbs Also See for Levelflex FMP55:
Table of Contents

Advertisement

Operating menu
Assign current output 1 to 2
Navigation
Description
Selection
Factory setting
Additional information
9)
only for devices with two current outputs
150
"Current output 1 to 2" submenu
The Current output 2 submenu (→  150) is only available for devices with two
current outputs.
Navigation
 Setup → Advanced setup → Curr.output 1 to 2
 Setup → Advanced setup → Curr.output 1 to 2 → Assign curr.
Select process variable for current output.
• Level linearized
• Distance
• Electronic temperature
• For FMP55: Measured capacitance
• Relative echo amplitude
• Analog output adv. diagnostics 1
• Analog output adv. diagnostics 2
Additionally for Operating mode = "Interface" or "Interface with capacitance":
• Interface linearized
• Interface distance
• Thickness upper layer
• Relative interface amplitude
For interface measurements
• Current output 1: Interface linearized
9)
• Current output 2
: Level linearized
Definition of the current range for the process variables
Process variable
Level linearized
Distance
Electronic temperature
Measured capacitance
Relative echo amplitude
Analog output adv.
diagnostics 1/2
Interface linearized
Interface distance
4 mA value
1)
0 %
or the associated
linearized value
0 (i.e. level is at the reference
point)
–50 °C (–58 °F)
0 pF
0 mV
depending on the parametrization of the Advanced Diagnostics
1)
0 %
or the associated
linearized value
0 (i.e. interface at the
reference point)
Levelflex FMP55 HART
20 mA value
2)
100 %
or the associated linearized value
Empty calibration (→  113) (i.e. level is at
0 %)
100 °C (212 °F)
4 000 pF
2 000 mV
2)
100 %
or the associated linearized value
Empty calibration (→  113) (i.e. interface
is at 0 %)
Endress+Hauser