Endress+Hauser Levelflex FMP55 Operating Instructions Manual page 129

Guided wave radar
Hide thumbs Also See for Levelflex FMP55:
Table of Contents

Advertisement

Levelflex FMP55 HART
Use calculated DC value
Navigation
Description
Selection
Factory setting
Additional information
Endress+Hauser
Setup → Advanced setup → Interface → Use calc. DC
Specify whether the calculated dielectric constant is to be used.
• Save and exit
• Cancel and exit
Cancel and exit
Meaning of the options
• Save and exit
The calculated constant is assumed to be the correct one.
• Cancel and exit
The calculated dielectric constant is rejected; the previous dielectric constant remains
active.
On the local display, the Calculated DC value parameter (→  128) is displayed
together with this parameter.
Operating menu
129