Vega VEGADIF 65 Operating Instructions Manual page 98

Foundation fieldbus, differential pressure transmitter
Table of Contents

Advertisement

11 Supplement
Version
B
D
F
U
1
2
3
Oval flange, connection ¼-18 NPT or RC ¼, with lateral ventilation
Fig. 62: 10 mbar and 30 mbar measuring cell
98
Connection
Fastening
1/4-18 NPT
7/16-20 UNF
IEC 61518
1/4-18 NPT
7/16-20 UNF
IEC 61518
1/4-18 NPT
7/16-20 UNF
IEC 61518
RC 1/4
7/16-20 UNF
1/4-18 NPT
PN 160: M10, PN
IEC 61518
420: M12
1/4-18 NPT
PN 160: M10, PN
IEC 61518
420: M12
1/4-18 NPT
PN 160: M10, PN
IEC 61518
420: M12
+ –
54 mm
(2.13")
100 mm
(3.94")
Material
Steel C 22.8
AISI 316L
Alloy C276
AISI 316L
Steel C 22.8
AISI 316L
Alloy C276
7/16-20 UNF
M 10
1/4-18 NPT
RC1/4
VEGADIF 65 • Foundation Fieldbus
Scope of delivery
incl. 2 vent valves
(316L)
incl. 2 vent valves
(316L)
without valves/clo-
sing screws
incl. 2 vent valves
(316L)
incl. 2 vent valves
(316L)
incl. 2 vent valves
(316L)
without valves/clo-
sing screws
1/4-18NPT
RC1/4
106 mm
(4.17")