Introduction
Application
VEGADIF 65 • Foundation Fieldbus
6 Adjustment with the indicating and adjustment module PLICSCOM

6.4 Parameter description

VEGADIF 65 has general adjustment parameters which are also used
for other measuring principles as well as instrument-specific adjust-
ment parameters. The general adjustment parameters are described
in the operating instructions manual "Indicating and adjustment
module".
The instrument-specific adjustment parameters are described in this
chapter.
Information:
If the adjustment limits of the adjustment parameters are exceeded,
the message "Outside parameter limits" appears. The editing
procedure can be aborted with [ESC] or the displayed limit value can
be accepted with [OK].
The VEGADIF 65 can be used for differential pressure, level, flow as
well as density and interface measurement. The selection of the
respective application is carried out in the menu item "Application".
Dependent on the selected application, the adjustment is carried out
as zero/span or min./max. adjustment.
Information:
The applications density and interface measurement are also realized
via the application level measurement.
Proceed as follows to switch over to the application differential
pressure or flow measurement:
1
Push the [OK] button in the measured value display, the menu
overview is displayed.
Basic settings
Display
Diagnostics
Service
Info
2
Confirm the menu "Basic adjustment" with [OK].
Application
Level
3
Confirm the menu item "Application" with [OK].
Warning:
Note the warning: "Output can change".
4
Select with [->] "OK" and confirm with [OK].