Vega VEGADIF 65 Operating Instructions Manual page 87

Foundation fieldbus, differential pressure transmitter
Table of Contents

Advertisement

Electromechanical data - version IP 66/IP 68 (1 bar)
Cable entry
Single chamber housing
-
Connection cable
Structure
-
Wire cross-section
-
Wire resistance
-
Tensile strength
-
Standard length
-
Max. length
-
Min. bending radius at 25 °C/77 °F
-
Diameter approx.
-
Colour - Non-Ex version
-
Colour - Ex-version
-
Electromechanical data - version IP 66/IP 68 with external electronics
Connection cable between IP 68 instrument and external housing:
Structure
-
Wire cross-section
-
Standard length
-
Max. length
-
Min. bending radius at 25 °C/77 °F
-
Diameter approx.
-
Colour
-
Cable entry/plug
25)
External housing
-
Spring-loaded terminals for wire cross-sec-
tion up to
Indicating and adjustment module
Voltage supply and data transmission
VEGADIF 65 • Foundation Fieldbus
l
or:
l
four wires, one suspension cable, one breather
capillary, screen braiding, metal foil, mantle
0.5 mm² (AWG 20)
< 0.036 Ω/m (0.011 Ω/ft)
> 1200 N (270 pounds force)
5 m (16.4 ft)
1000 m (3281 ft)
25 mm (0.985 in)
8 mm (0.315 in)
Black
Blue
Four wires, screen braiding, inner cover, screen
braiding, outer cover
0.5 mm² (AWG 20)
5 m (16.40 ft)
25 m (82.02 ft)
25 mm (0.985 in)
8 mm (0.315 in)
Blue
l
or:
l
2.5 mm² (AWG 14)
through the sensor
Depending on the version M12 x 1, according to ISO 4400, Harting, 7/8" FF.
25)
1 x IP 68 cable gland M20 x 1.5; 1 x blind
stopper M20 x 1.5
1 x closing cap ½ NPT, 1 x blind plug ½ NPT
2 x cable gland M20 x 1.5 (cable: ø 5 ... 9 mm),
1 x blind stopper M20 x 1.5
1 x cable gland M20 x 1.5, 1 x plug (depending
on version), 1 x blind stopper M20 x 1.5
11 Supplement
87

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents