Front Panel Features - Extron electronics SW2 DP User Manual

Displayport
Hide thumbs Also See for SW2 DP:
Table of Contents

Advertisement

Operation
This section contains a description of the features available on the SW2 DP front panel and
provides procedures for operating the switcher.

Front Panel Features

1
AUTO
SWITCH
Figure 9.
1
2
3
Front Panel Features
Operations
2
INPUTS
1
CONFIG
5
SW2 DP Front Panel
Auto Switch Active LED — This green LED lights when auto-input switching is in
effect (see
Enabling Auto-input Switching
auto-input switching).
Input selection buttons and LEDs — Press these buttons to select input 1 or
2. The LED at the right of each button lights when the SW2 DP has power and the
corresponding input is selected.
The input buttons are disabled if auto-input switching is in effect; however, the LEDs
continue to light to indicate the selected input.
The SW2 DP retains the previously selected input during a power cycle and the LED
for that input continues to light.
The input buttons are also used for enabling front panel lockout (executive mode) and
to initiate a system reset (see
Resetting, both on page 14).
Signal status LEDs —
Inputs: Each input has a corresponding numbered Signal LED, which illuminates
when a source is connected to the input connector and Main Link activity is
detected from it.
NOTE: If the source device connected to the selected input is HDCP encrypted
(requires HDCP authentication), the corresponding signal LED may not light
unless HDCP has been authenticated.
Output: The Output Signal LED lights when the Main Link signal is being
transmitted to a connected output device.
2
on page 8 for the procedure to set up
Enabling Front Panel Lockout (Executive Mode)
3
INPUTS OUTPUT
SIGNAL
1
2
HDCP
SW2 DP
DISPLAYPORT SWITCHER
4
and
SW2 DP • Operation
12

Advertisement

Table of Contents
loading

Table of Contents