Backlight Power Select
JP16 is used to select the power level of backlight brightness control: +5V or +3.3V.
Important:
Before powering-on the system, make sure that the power settings of JP16 match the
power specification of backlight control. Selecting the incorrect voltage will seriously
damage the backlight.
Chapter 2 Hardware Installation
Chapter 2
1
2
3
JP16
1-2 On: +5V
1
2
3
2-3 On: +3.3V (default)
18
LCD/Inverter Power Select
JP21 is used to select the power level of the LCD/inverter power connector.
1
2
3
1-2 On: +12V
JP21
1
2
3
2-3 On: +5V (default)
www.dfi .com