Removal and replacement of the Brocade DCX chassis
5.
Display and record the manufacturer serial numbers.
Enter chassisShow ; then copy the command output into the config-miscinfo.txt file.
"Factory Serial Num" and "Serial Num" are listed under "Chassis/WWN Unit 1." If the current WWN cards are the original cards,
the factory serial number listed is the same as the chassis serial number.
switch:admin> chassisshow
Chassis Backplane Revision: 1F
SW BLADE
Slot: 1
Header Version:
Power Consume Factor:
Factory Part Num:
Factory Serial Num:
Manufacture:
Update:
Time Alive:
Time Awake:
<output truncated>
CHASSIS/WWN
Header Version:
Power Consume Factor:
Factory Part Num:
Factory Serial Num:
Manufacture:
Update:
Time Alive:
Time Awake:
<output truncated>
switch:admin>
6.
Create a SAN "profile" by entering and recording the information provided by the following commands:
nsShow
nsAllShow
switchShow
fabricShow
Copy the command output into a text file named "SANbefor.txt." After the Brocade DCX is restored to the fabric, this information
can be used to verify that no unintentional changes have occurred to the fabric.
switch:admin>
Enter Pid COS PortName NodeName TTL
<output truncated>
switch:admin> nsallshow
12 Nx_Ports in the Fabric
<output truncated>
switch:admin> switchshow
switchName: switch
<output truncated>
switch:admin> fabricshow
Switch ID Worldwide Name Enet IP Addr FC IP Addr Name
<output truncated>
switch:admin>
128
2
-50
60-0001532-03
KP000000195
Day:
1
Month:
Day: 14
Month:
187 days
3 days
Unit: 1
(in same assembly as WWN Unit: 2)
2
-3
60-0001501-07
FT02X805BE2
Day: 26
Month:
Day: 14
Month:
207 days
3 days
nsshow
1
Year: 2007
3
Year: 2012
3
Year: 2007
3
Year: 2009
Brocade DCX Backbone Hardware Installation Guide
53-1000685-24

Advertisement

Table of Contents
loading

Table of Contents