4.
Run the following commands on the chassis before replacing the cards so that the data can be verified after the replacement:
1.
licenseidshow
2.
ipaddrshow
3.
switchname
4.
chassisname
5.
wwncardshow ipdata
6.
chassisshow (look at the WWN and Chassis information at the bottom)
7.
ficonshow switchrnid (FICON/mainframe environments only)
8.
configupload
The factory serial number and the sequence number in the following outputs should match, except in the ficonshow switchrnid,
which will have a number appended to the front indicating that the logical switch number, if virtual fabrics is enabled:
switch:FID128:admin> chassisshow
<output truncated>
WWN
Unit: 1
Header Version:
Power Consume Factor:
Factory Part Num:
Factory Serial Num:
Manufacture:
Update:
Time Alive:
Time Awake:
WWN
Unit: 2
Header Version:
Power Consume Factor:
Factory Part Num:
Factory Serial Num:
Manufacture:
Update:
Time Alive:
Time Awake:
Chassis Factory Serial Num: AFY2530G00S
switch:admin> ficonshow switchrnid
{
{Switch WWN
10:00:00:05:1e:95:b1:00
Type number:
Model number:
Manufacturer:
Plant of Manufacture: CA
Sequence Number:
tag:
}
Brocade DCX Backbone Hardware Installation Guide
53-1000685-24
2
-1
60-1000491-05
AFX2533G001
Day: 19
Month:
1
Year: 2012
Day:
5
Month:
5
Year: 2014
756 days
3 days
2
-1
60-1000491-05
AJX0416G02H
Day: 12
Month:
8
Year: 2011
Day:
5
Month:
5
Year: 2014
897 days
3 days
Flag Parm
0x00 0x200a00
SLKWRM
DCX
BRD
0AFX2533G001
b6ff
WWN card removal and replacement
111