Remote Syringe Preparation; 200 Hour Service - SRAM RockShox Reverb Stealth Manual

Bleed manual hydraulic hose replacement remote system bleed
Hide thumbs Also See for RockShox Reverb Stealth:
Table of Contents

Advertisement

5 0 / 2 0 0 H o u r S e r v i c e
Install the Bleeding Edge™ syringe bleed tool onto one RockShox®
1
syringe.
Draw 20 mL of Reverb™ hydraulic fluid into the syringe.
Hold the syringe upright, cover the tip with a rag, and gently depress
the plunger to purge any air bubbles from the syringe.
Only use the syringes included with the RockShox Bleed kit.
Do not use syringes that have been in contact with DOT brake fluid.
DOT brake fluid will permanently damage the seals and cause the
seatpost to malfunction.
Standard Remote: Remove the bleed screw and thread the standard
2
syringe bleed fitting into the remote bleed port.
Reverb 1x Remote: To open the system, turn the bleed port screw
counter-clockwise one quarter turn. Then turn the bleed port screw
clockwise until light resistance is felt, then stop.
The bleed port must be opened with a hex wrench the first time it is
opened.
Insert the Bleeding Edge syringe bleed fitting into the remote bleed
port, and push down until the 3 mm hex end is engaged with the bleed
port. Turn the bleed fitting 1/4 to 1 full turn counter-clockwise to open
the bleed system.
Standard Remote Bleed: Proceed to
Reverb 1x Remote Bleed: Proceed to
R e m o t e S y r i n g e P r e p a r a t i o n
NOTI CE
Remote Bleed -
Standard.
Remote Bleed - Reverb 1x
Standard Remote - Standard Syringe
T10 TORX®
Standard Remote
3 mm Hex
Reverb 1x Remote
Bleeding Edge Tool
Remote.
Reverb 1x™ Remote - Bleeding Edge Syringe
Reverb 1x Remote

Remote Syringe Preparation

25