SRAM RockShox Reverb Stealth Manual page 31

Bleed manual hydraulic hose replacement remote system bleed
Hide thumbs Also See for RockShox Reverb Stealth:
Table of Contents

Advertisement

Slowly push the syringe plunger down while simultaneously slowly
4
releasing the remote lever, applying light opposing pressure on the
lever, then release pressure from the syringe.
Do not release pressure from the remote lever until it is fully extended.
When the remote lever is fully extended, release pressure from the
syringe.
Repeat this process (steps 1 through 4) five to six times, until no
bubbles, or very few bubbles, are visible exiting the lever.
Air bubbles will be visible exiting the remote during this process.
While pressing down lightly, turn the Bleeding Edge™ tool clockwise
5
until it stops. Turn the tool with a moderate amount of additional torque
to close the bleed port.
Hold the wings on the Bleeding Edge tool to apply torque while
turning.
The system is now closed.
While applying light opposing pressure to the syringe body, slowly pull
6
up on the syringe plunger to draw a vacuum.
Hold the plunger in the extended drawn position.
Do not pull the syringe plunger without applying opposing pressure
to the syringe body or Bleeding Edge tool. Excessive force will pull
the bleed fitting out of the remote lever
NOTI CE
Bleeding Edge Tool
Remote Bleed - Reverb™ 1x™ Remote
31