I

Reset Modes

Pressing the rear panel reset button (see
Tweeker will reset only the Dante module in the AXI, leaving the gain and phantom power
settings unaffected. There are two reset modes that can be activated via the rear panel reset
button.

Reset Mode 1

Press the rear panel reset button and quickly release it to cause a hardware reset of the
Dante module while preserving all of its settings such as IP configuration, routing, device
name, channel names, and sampling rate.

Reset Mode 2

To cause an absolute system reset of the Dante module back to factory default conditions,
press and hold the rear panel reset button for 10 seconds until the AT (PoE) port LEDs flash.
Following this reset, the Dante module will proceed to its normal boot sequence. This reset
will:
Input and Output Signal and Clip LEDs — The green signal LEDs light steadily
when signal is present and increase in intensity from -60 dBFS (lowest intensity, signal
presence indication) to -1 dBFS (full brightness). The red clip LEDs light steadily at
-1 dBFS to indicate clipping and stay lit for one second beyond receiving the clip
message.
Set the IP configuration to default settings
Clear all audio channel routing
Set the Dante device name and channel names to default