Problem solving guide
Problem
Interruption to the
power supply during
operation
The In-operation
indicator is flashing
quickly. The buzzer is
sounding. One of the
following faults appears
in the display:
Fault FXX
Waterproof
50
Cause and remedy
If a temporary interruption to the power supply
occurs during a programme sequence, no action is
required.
The programme will continue after the interruption.
If the temperature in the wash cabinet drops below
the minimum value required for the programme block
during the interruption to the power supply, the
programme block will be repeated.
If there has been an interruption to the power supply
of ≥ 20 hours, the entire programme will be repeated.
Before rectifying the problem:
 Switch the dishwasher off with the  button.
There may be a technical fault.
After a few seconds:
 Switch the dishwasher back on.
 Select the programme you want.
 Close the door.
If the fault message appears again, there is a
technical fault.
 Call Miele Service.
The Waterproof system has reacted.
 Close the stopcock.
 Call Miele Service.