Plumbing; The Miele Waterproof System; Connection To The Water Supply - Miele PG 8083 SCVi Operating Instructions Manual

Commercial
Hide thumbs Also See for PG 8083 SCVi:
Table of Contents

Advertisement

The Miele Waterproof system

Provided your dishwasher has been
installed correctly, the Miele Waterproof
system will provide protection against
water damage throughout its lifetime.

Connection to the water supply

The water in the dishwasher
must not be used as drinking water.
– The dishwasher must be connected
to the water supply in strict
accordance with current local and
national water authority regulations.
– The water used must at least comply
with European regulations for
drinking water quality.
If the water supply has a high iron
content there is a danger of corrosion
occurring on items being cleaned in
the dishwasher, as well as the
machine itself.
If the chloride content of the water
exceeds 100 mg/l the risk of
corrosion to items being cleaned in
the dishwasher will be further
increased.
– In certain regions (e.g. mountainous
regions), the water composition may
cause precipitates to form, requiring
the use of softened water for the
dishwasher.
– UK only: To comply with water
regulation requirements, this
dishwasher must be connected to the
drinking water supply via the check
valve supplied with the machine.
– The water pressure (flow pressure at
the take-off point) must be between
30 and 1000 kPa (0.3 and 10 bar).
If the water pressure is lower than
this, the fault message
appear in the display (see "Problem
solving guide").
If the water pressure is too high, a
pressure reducer valve must be fitted.
– A stopcock valve with a
thread must be provided on site. It
should be easily accessible so that
the water supply can be turned off
when the dishwasher is not in use.
– The DN 10 inlet hose is approx. 1.5 m
long terminating in a
thread. A 1.5 m long flexible metal
extension hose tested to 140 bar
(14,000 kPa) is available as an
optional accessory if required. On no
account may the inlet filter be
removed.

Plumbing

will
Inlet
3
/
inch male
4
3
/
 inch female
4
65

Advertisement

Table of Contents
loading

Table of Contents