B.4 MEMORY MAPPING
Table B–9: MODBUS MEMORY MAP (Sheet 44 of 51)
ADDR
REGISTER NAME
C500
...Repeated for Contact Output 17
C50C
...Repeated for Contact Output 18
C518
...Repeated for Contact Output 19
C524
...Repeated for Contact Output 20
C530
...Repeated for Contact Output 21
B
C53C
...Repeated for Contact Output 22
C548
...Repeated for Contact Output 23
C554
...Repeated for Contact Output 24
C560
...Repeated for Contact Output 25
C56C
...Repeated for Contact Output 26
C578
...Repeated for Contact Output 27
C584
...Repeated for Contact Output 28
C590
...Repeated for Contact Output 29
C59C
...Repeated for Contact Output 30
C5A8
...Repeated for Contact Output 31
C5B4
...Repeated for Contact Output 32
C5C0
...Repeated for Contact Output 33
C5CC
...Repeated for Contact Output 34
C5D8
...Repeated for Contact Output 35
C5E4
...Repeated for Contact Output 36
C5F0
...Repeated for Contact Output 37
C5FC
...Repeated for Contact Output 38
C608
...Repeated for Contact Output 39
C614
...Repeated for Contact Output 40
C620
...Repeated for Contact Output 41
C62C
...Repeated for Contact Output 42
C638
...Repeated for Contact Output 43
C644
...Repeated for Contact Output 44
C650
...Repeated for Contact Output 45
C65C
...Repeated for Contact Output 46
C668
...Repeated for Contact Output 47
C674
...Repeated for Contact Output 48
C680
...Repeated for Contact Output 49
C68C
...Repeated for Contact Output 50
C698
...Repeated for Contact Output 51
C6A4
...Repeated for Contact Output 52
C6B0
...Repeated for Contact Output 53
C6BC
...Repeated for Contact Output 54
C6C8
...Repeated for Contact Output 55
C6D4
...Repeated for Contact Output 56
C6E0
...Repeated for Contact Output 57
C6EC
...Repeated for Contact Output 58
C6F8
...Repeated for Contact Output 59
C704
...Repeated for Contact Output 60
C710
...Repeated for Contact Output 61
C71C
...Repeated for Contact Output 62
C728
...Repeated for Contact Output 63
C734
...Repeated for Contact Output 64
Reset (Read/Write Setting)
C750
FlexLogic™ operand which initiates a reset
Control Pushbuttons (Read/Write Setting) (7 modules)
C760
Control Pushbutton 1 Function
C761
Control Pushbutton 1 Events
C762
...Repeated for Control Pushbutton 2
B-52
RANGE
0 to 65535
0 to 1
0 to 1
D30 Line Distance Protection System
APPENDIX B
UNITS
STEP
FORMAT
---
1
F300
---
1
F102
---
1
F102
DEFAULT
0
0 (Disabled)
0 (Disabled)