Table B–9: MODBUS MEMORY MAP (Sheet 11 of 51)
ADDR
REGISTER NAME
40A9
DNP Unsolicited Responses Function
40AA
DNP Unsolicited Responses Timeout
40AB
DNP unsolicited responses maximum retries
40AC
DNP unsolicited responses destination address
40AD
Ethernet operation mode
40AE
DNP current scale factor
40AF
DNP voltage scale factor
40B0
DNP power scale factor
40B1
DNP energy scale factor
40B2
DNP power scale factor
40B3
DNP other scale factor
40B4
DNP current default deadband
40B6
DNP voltage default deadband
40B8
DNP power default deadband
40BA
DNP energy default deadband
40BE
DNP other default deadband
40C0
DNP IIN time synchronization bit period
40C1
DNP message fragment size
40C2
DNP client address 3
40C4
DNP client address 4
40C6
DNP client address 5
40C8
DNP number of paired binary output control points
40C9
DNP TCP connection timeout
40CA
Reserved (22 items)
40E0
TCP port number for the IEC 60870-5-104 protocol
40E1
IEC 60870-5-104 protocol function
40E2
IEC 60870-5-104 protocol common address of ASDU
40E3
IEC 60870-5-104 protocol cyclic data transmit period
40E4
IEC 60870-5-104 current default threshold
40E6
IEC 60870-5-104 voltage default threshold
40E8
IEC 60870-5-104 power default threshold
40EA
IEC 60870-5-104 energy default threshold
40EC
IEC 60870-5-104 power default threshold
40EE
IEC 60870-5-104 other default threshold
40F0
IEC 60870-5-104 client address (5 items)
4104
IEC 60870-5-104 redundancy port
4005
Reserved (59 items)
4140
DNP object 1 default variation
4141
DNP object 2 default variation
4142
DNP object 20 default variation
4143
DNP object 21 default variation
4144
DNP object 22 default variation
4145
DNP object 23 default variation
4146
DNP object 30 default variation
4147
DNP object 32 default variation
Ethernet switch (Read/Write Setting)
4148
Ethernet switch IP address
414A
Ethernet switch Modbus IP port number
414B
Ethernet switch Port 1 Events
414C
Ethernet switch Port 2 Events
414D
Ethernet switch Port 3 Events
414E
Ethernet switch Port 4 Events
414F
Ethernet switch Port 5 Events
4150
Ethernet switch Port 6 Events
GE Multilin
RANGE
0 to 1
0 to 60
1 to 255
0 to 65519
0 to 1
0 to 8
0 to 8
0 to 8
0 to 8
0 to 8
0 to 8
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
1 to 10080
30 to 2048
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 32
10 to 65535
0 to 1
1 to 65535
0 to 1
0 to 65535
1 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 4294967295
0 to 1
0 to 1
1 to 2
1 to 3
0 to 3
0 to 3
0 to 3
0 to 3
1 to 5
0 to 5
0 to 4294967295
1 to 65535
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
D30 Line Distance Protection System
B.4 MEMORY MAPPING
UNITS
STEP
FORMAT
---
1
F102
s
1
F001
---
1
F001
---
1
F001
---
1
F192
---
1
F194
---
1
F194
---
1
F194
---
1
F194
---
1
F194
---
1
F194
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
min
1
F001
---
1
F001
---
1
F003
---
1
F003
---
1
F003
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F102
---
1
F001
s
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F003
---
1
F126
---
1
F001
---
1
F001
---
1
F001
---
1
F523
---
1
F524
---
1
F523
---
1
F523
---
1
F001
---
1
F525
---
1
F003
---
1
F001
---
1
F102
---
1
F102
---
1
F102
---
1
F102
---
1
F102
---
1
F102
DEFAULT
0 (Disabled)
5
10
1
0 (Half-Duplex)
B
2 (1)
2 (1)
2 (1)
2 (1)
2 (1)
2 (1)
30000
30000
30000
30000
30000
1440
240
0
0
0
0
120
0
2404
0 (Disabled)
0
60
30000
30000
30000
30000
30000
30000
0
0 (No)
0
2
2
0 (1)
0 (1)
0 (1)
0 (1)
1
0 (1)
3232235778
502
0 (Disabled)
0 (Disabled)
0 (Disabled)
0 (Disabled)
0 (Disabled)
0 (Disabled)
B-19