B.4 MEMORY MAPPING
Table B–9: MODBUS MEMORY MAP (Sheet 46 of 51)
ADDR
REGISTER NAME
C8F4
...Repeated for Direct Input 26
C8F8
...Repeated for Direct Input 27
C8FC
...Repeated for Direct Input 28
C900
...Repeated for Direct Input 29
C904
...Repeated for Direct Input 30
B
C908
...Repeated for Direct Input 31
C90C
...Repeated for Direct Input 32
Platform Direct Outputs (Read/Write Setting) (96 modules)
CA10
Direct Output 1 Operand
CA11
Direct Output 1 Events
CA12
...Repeated for Direct Output 2
CA14
...Repeated for Direct Output 3
CA16
...Repeated for Direct Output 4
CA18
...Repeated for Direct Output 5
CA1A
...Repeated for Direct Output 6
CA1C
...Repeated for Direct Output 7
CA1E
...Repeated for Direct Output 8
CA20
...Repeated for Direct Output 9
CA22
...Repeated for Direct Output 10
CA24
...Repeated for Direct Output 11
CA26
...Repeated for Direct Output 12
CA28
...Repeated for Direct Output 13
CA2A
...Repeated for Direct Output 14
CA2C
...Repeated for Direct Output 15
CA2E
...Repeated for Direct Output 16
CA30
...Repeated for Direct Output 17
CA32
...Repeated for Direct Output 18
CA34
...Repeated for Direct Output 19
CA36
...Repeated for Direct Output 20
CA38
...Repeated for Direct Output 21
CA3A
...Repeated for Direct Output 22
CA3C
...Repeated for Direct Output 23
CA3E
...Repeated for Direct Output 24
CA40
...Repeated for Direct Output 25
CA42
...Repeated for Direct Output 26
CA44
...Repeated for Direct Output 27
CA46
...Repeated for Direct Output 28
CA48
...Repeated for Direct Output 29
CA4A
...Repeated for Direct Output 30
CA4C
...Repeated for Direct Output 31
CA4E
...Repeated for Direct Output 32
Direct Input/Output Alarms (Read/Write Setting)
CAD0
Direct Input/Output Channel 1 CRC Alarm Function
CAD1
Direct I/O Channel 1 CRC Alarm Message Count
CAD2
Direct Input/Output Channel 1 CRC Alarm Threshold
CAD3
Direct Input/Output Channel 1 CRC Alarm Events
CAD4
Reserved (4 items)
CAD8
Direct Input/Output Channel 2 CRC Alarm Function
CAD9
Direct I/O Channel 2 CRC Alarm Message Count
CADA
Direct Input/Output Channel 2 CRC Alarm Threshold
CADB
Direct Input/Output Channel 2 CRC Alarm Events
CADC
Reserved (4 items)
CAE0
Direct I/O Ch 1 Unreturned Messages Alarm Function
CAE1
Direct I/O Ch 1 Unreturned Messages Alarm Msg Count
B-54
RANGE
0 to 65535
0 to 1
0 to 1
100 to 10000
1 to 1000
0 to 1
1 to 1000
0 to 1
100 to 10000
1 to 1000
0 to 1
1 to 1000
0 to 1
100 to 10000
D30 Line Distance Protection System
APPENDIX B
UNITS
STEP
FORMAT
---
1
F300
---
1
F102
---
1
F102
---
1
F001
---
1
F001
---
1
F102
---
1
F001
---
1
F102
---
1
F001
---
1
F001
---
1
F102
---
1
F001
---
1
F102
---
1
F001
DEFAULT
0
0 (Disabled)
0 (Disabled)
600
10
0 (Disabled)
10
0 (Disabled)
600
10
0 (Disabled)
10
0 (Disabled)
600