B.4 MEMORY MAPPING
Table B–9: MODBUS MEMORY MAP (Sheet 17 of 53)
ADDR
REGISTER NAME
4D60
...Repeated for User-Definable Display 12
4D80
...Repeated for User-Definable Display 13
4DA0
...Repeated for User-Definable Display 14
4DC0
...Repeated for User-Definable Display 15
4DE0
...Repeated for User-Definable Display 16
B
User Programmable Pushbuttons (Read/Write Setting) (12 modules)
4E00
User Programmable Pushbutton 1 Function
4E01
User Programmable Pushbutton 1 Top Line
4E0B
User Programmable Pushbutton 1 On Text
4E15
User Programmable Pushbutton 1 Off Text
4E1F
User Programmable Pushbutton 1 Drop-Out Time
4E20
User Programmable Pushbutton 1 Target
4E21
User Programmable Pushbutton 1 Events
4E22
User Programmable Pushbutton 1 LED Operand
4E23
User Programmable Pushbutton 1 Autoreset Delay
4E24
User Programmable Pushbutton 1 Autoreset Function
4E25
User Programmable Pushbutton 1 Local Lock
4E26
User Programmable Pushbutton 1 Message Priority
4E27
User Programmable Pushbutton 1 Remote Lock
4E28
User Programmable Pushbutton 1 Reset
4E29
User Programmable Pushbutton 1 Set
4E2A
...Repeated for User Programmable Pushbutton 2
4E54
...Repeated for User Programmable Pushbutton 3
4E7E
...Repeated for User Programmable Pushbutton 4
4EA8
...Repeated for User Programmable Pushbutton 5
4ED2
...Repeated for User Programmable Pushbutton 6
4EFC
...Repeated for User Programmable Pushbutton 7
4F26
...Repeated for User Programmable Pushbutton 8
4F50
...Repeated for User Programmable Pushbutton 9
4F7A
...Repeated for User Programmable Pushbutton 10
4FA4
...Repeated for User Programmable Pushbutton 11
4FCE
...Repeated for User Programmable Pushbutton 12
Flexlogic (Read/Write Setting)
5000
FlexLogic™ Entry (512 items)
RTD Inputs (Read/Write Setting) (48 modules)
5400
RTD Input 1 Function
5401
RTD Input 1 ID
5407
RTD Input 1 Type
5413
...Repeated for RTD Input 2
5426
...Repeated for RTD Input 3
5439
...Repeated for RTD Input 4
544C
...Repeated for RTD Input 5
545F
...Repeated for RTD Input 6
5472
...Repeated for RTD Input 7
5485
...Repeated for RTD Input 8
5498
...Repeated for RTD Input 9
54AB
...Repeated for RTD Input 10
54BE
...Repeated for RTD Input 11
54D1
...Repeated for RTD Input 12
54E4
...Repeated for RTD Input 13
54F7
...Repeated for RTD Input 14
550A
...Repeated for RTD Input 15
551D
...Repeated for RTD Input 16
5530
...Repeated for RTD Input 17
B-24
RANGE
0 to 2
0 to 60
0 to 2
0 to 1
0 to 65535
0 to 600
0 to 1
0 to 65535
0 to 2
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 1
0 to 3
C70 Capacitor Bank Protection and Control System
UNITS
STEP
---
1
---
---
---
---
---
---
---
---
---
s
0.05
---
1
---
1
---
1
s
0.05
---
1
---
1
---
1
---
1
---
1
---
1
---
1
---
1
---
---
---
---
1
APPENDIX B
FORMAT
DEFAULT
F109
2 (Disabled)
F202
(none)
F202
(none)
F202
(none)
F001
0
F109
0 (Self-reset)
F102
0 (Disabled)
F300
0
F001
0
F102
0 (Disabled)
F300
0
F220
0 (Disabled)
F300
0
F300
0
F300
0
F300
16384
F102
0 (Disabled)
F205
"RTD Ip 1"
F174
0 (100 ohm Platinum)
GE Multilin