GE UR Series C70 Instruction Manual page 501

Capacitor bank protection and control system
Table of Contents

Advertisement

APPENDIX B
Table B–9: MODBUS MEMORY MAP (Sheet 26 of 53)
ADDR
REGISTER NAME
7F20
...Repeated for Neutral Overvoltage 3
Auxiliary Overvoltage (Read/Write Grouped Setting) (3 modules)
7F30
Auxiliary Overvoltage 1 Function
7F31
Auxiliary Overvoltage 1 Signal Source
7F32
Auxiliary Overvoltage 1 Pickup
7F33
Auxiliary Overvoltage 1 Pickup Delay
7F34
Auxiliary Overvoltage 1 Reset Delay
7F35
Auxiliary Overvoltage 1 Block
7F36
Auxiliary Overvoltage 1 Target
7F37
Auxiliary Overvoltage 1 Events
7F38
Reserved (8 items)
7F40
...Repeated for Auxiliary Overvoltage 2
7F50
...Repeated for Auxiliary Overvoltage 3
Frequency (Read Only)
8000
Tracking Frequency
Breaker Failure (Read/Write Grouped Setting) (2 modules)
8600
Breaker Failure 1 Function
8601
Breaker Failure 1 Mode
8602
Breaker Failure 1 Source
8603
Breaker Failure 1 Amp Supervision
8604
Breaker Failure 1 Use Seal-In
8605
Breaker Failure 1 Three Pole Initiate
8606
Breaker Failure 1 Block
8607
Breaker Failure 1 Phase Amp Supv Pickup
8608
Breaker Failure 1 Neutral Amp Supv Pickup
8609
Breaker Failure 1 Use Timer 1
860A
Breaker Failure 1 Timer 1 Pickup
860B
Breaker Failure 1 Use Timer 2
860C
Breaker Failure 1 Timer 2 Pickup
860D
Breaker Failure 1 Use Timer 3
860E
Breaker Failure 1 Timer 3 Pickup
860F
Breaker Failure 1 Breaker Status 1 Phase A/3P
8610
Breaker Failure 1 Breaker Status 2 Phase A/3P
8611
Breaker Failure 1 Breaker Test On
8612
Breaker Failure 1 Phase Amp Hiset Pickup
8613
Breaker Failure 1 Neutral Amp Hiset Pickup
8614
Breaker Failure 1 Phase Amp Loset Pickup
8615
Breaker Failure 1 Neutral Amp Loset Pickup
8616
Breaker Failure 1 Loset Time
8617
Breaker Failure 1 Trip Dropout Delay
8618
Breaker Failure 1 Target
8619
Breaker Failure 1 Events
861A
Breaker Failure 1 Phase A Initiate
861B
Breaker Failure 1 Phase B Initiate
861C
Breaker Failure 1 Phase C Initiate
861D
Breaker Failure 1 Breaker Status 1 Phase B
861E
Breaker Failure 1 Breaker Status 1 Phase C
861F
Breaker Failure 1 Breaker Status 2 Phase B
8620
Breaker Failure 1 Breaker Status 2 Phase C
8621
...Repeated for Breaker Failure 2
8642
...Repeated for Breaker Failure 3
8663
...Repeated for Breaker Failure 4
8684
...Repeated for Breaker Failure 5
86A5
...Repeated for Breaker Failure 6
GE Multilin
RANGE
0 to 1
0 to 5
0 to 3
0 to 600
0 to 600
0 to 65535
0 to 2
0 to 1
0 to 65535
0 to 1
0 to 1
0 to 5
0 to 1
0 to 1
0 to 65535
0 to 65535
0.001 to 30
0.001 to 30
0 to 1
0 to 65.535
0 to 1
0 to 65.535
0 to 1
0 to 65.535
0 to 65535
0 to 65535
0 to 65535
0.001 to 30
0.001 to 30
0.001 to 30
0.001 to 30
0 to 65.535
0 to 65.535
0 to 2
0 to 1
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
C70 Capacitor Bank Protection and Control System
UNITS
STEP
---
1
---
1
pu
0.001
s
0.01
s
0.01
---
1
---
1
---
1
---
1
---
Hz
---
---
1
---
1
---
1
---
1
---
1
---
1
---
1
pu
0.001
pu
0.001
---
1
s
0.001
---
1
s
0.001
---
1
s
0.001
---
1
---
1
---
1
pu
0.001
pu
0.001
pu
0.001
pu
0.001
s
0.001
s
0.001
---
1
---
1
---
1
---
1
---
1
---
1
---
1
---
1
---
1
B.4 MEMORY MAPPING
FORMAT
DEFAULT
F102
0 (Disabled)
F167
0 (SRC 1)
F001
300
F001
100
F001
100
F300
0
F109
0 (Self-reset)
F102
0 (Disabled)
F001
0
F001
0
F102
0 (Disabled)
F157
0 (3-Pole)
F167
0 (SRC 1)
F126
1 (Yes)
F126
1 (Yes)
F300
0
F300
0
F001
1050
F001
1050
F126
1 (Yes)
F001
0
F126
1 (Yes)
F001
0
F126
1 (Yes)
F001
0
F300
0
F300
0
F300
0
F001
1050
F001
1050
F001
1050
F001
1050
F001
0
F001
0
F109
0 (Self-reset)
F102
0 (Disabled)
F300
0
F300
0
F300
0
F300
0
F300
0
F300
0
F300
0
B-33
B

Advertisement

Table of Contents
loading

Table of Contents