Table B–10: MODBUS MEMORY MAP (Sheet 19 of 65)
ADDR
REGISTER NAME
4098
Port 2 Link Loss Alert
4099
Port 3 Link Loss Alert
409A
DNP Channel 1 Port
409B
DNP Channel 2 Port
409C
DNP Address
409E
DNP Client Addresses (2 items)
40A3
TCP Port Number for the Modbus Protocol
40A4
TCP/UDP Port Number for the DNP Protocol
40A5
TCP Port Number for the HTTP (Web Server) Protocol
40A6
Main UDP Port Number for the TFTP Protocol
40A7
Data Transfer UDP Port Numbers for the TFTP Protocol
(zero means "automatic") (2 items)
40A9
DNP Unsolicited Responses Function
40AA
DNP Unsolicited Responses Timeout
40AB
DNP Unsolicited Responses Maximum Retries
40AC
DNP Unsolicited Responses Destination Address
40AD
Ethernet Operation Mode
40AE
DNP Current Scale Factor
40AF
DNP Voltage Scale Factor
40B0
DNP Power Scale Factor
40B1
DNP Energy Scale Factor
40B2
DNP Power Scale Factor
40B3
DNP Other Scale Factor
40B4
DNP Current Default Deadband
40B6
DNP Voltage Default Deadband
40B8
DNP Power Default Deadband
40BA
DNP Energy Default Deadband
40BC
DNP Power Factor Default Deadband
40BE
DNP Other Default Deadband
40C0
DNP IIN Time Synchronization Bit Period
40C1
DNP Message Fragment Size
40C2
DNP Client Address 3
40C4
DNP Client Address 4
40C6
DNP Client Address 5
40C8
DNP Number of Paired Binary Output Control Points
40C9
DNP TCP Connection Timeout
40CA
DNP Communications Reserved (22 items)
40E0
TCP Port Number for the IEC 60870-5-104 Protocol
40E1
IEC 60870-5-104 Protocol Function
40E2
IEC 60870-5-104 Protocol Common Address of ASDU
40E3
IEC 60870-5-104 Protocol Cyclic Data Transmission Period
40E4
IEC 60870-5-104 Current Default Threshold
40E6
IEC 60870-5-104 Voltage Default Threshold
40E8
IEC 60870-5-104 Power Default Threshold
40EA
IEC 60870-5-104 Energy Default Threshold
40EC
IEC 60870-5-104 Power Factor Default Threshold
40EE
IEC 60870-5-104 Other Default Threshold
40F0
IEC 60870-5-104 Client Address (5 items)
4104
IEC 60870-5-104 Redundancy Port Enabled/Disabled
4105
Port 2 IP Address
4107
Port 2 IP Subnet Mask
4109
Port 2 Gateway IP Address
410B
PRT2 Ethernet Operation Mode
410C
PRT2 Redundancy Enabled
GE Multilin
N60 Network Stability and Synchrophasor Measurement System
RANGE
UNITS
0 to 1
---
0 to 1
---
0 to 5
---
0 to 5
---
0 to 65519
---
0 to 4294967295
---
0 to 65535
---
0 to 65535
---
0 to 65535
---
0 to 65535
---
0 to 65535
---
0 to 1
---
0 to 60
s
1 to 255
---
0 to 65519
---
0 to 1
---
0 to 8
---
0 to 8
---
0 to 8
---
0 to 8
---
0 to 8
---
0 to 8
---
0 to 100000000
---
0 to 100000000
---
0 to 100000000
---
0 to 100000000
---
0 to 100000000
--
0 to 100000000
---
1 to 10080
min
30 to 2048
---
0 to 4294967295
---
0 to 4294967295
---
0 to 4294967295
---
0 to 32
---
10 to 7200
s
0 to 1
---
0 to 65535
---
0 to 1
---
0 to 65535
---
1 to 65535
s
0 to 100000000
---
0 to 100000000
---
0 to 100000000
---
0 to 100000000
---
0 to1
---
0 to 100000000
---
0 to 4294967295
---
0 to 1
---
0 to 4294967295
---
0 to 4294967295
---
0 to 4294967295
---
0 to 1
---
0 to 2
---
B.4 MEMORY MAPPING
STEP
FORMAT
DEFAULT
1
F102
0 (Disabled)
1
F102
0 (Disabled)
1
F177
0 (None)
1
F177
0 (None)
1
F001
1
1
F003
0
1
F001
502
1
F001
20000
1
F001
80
1
F001
69
1
F001
0
1
F102
0 (Disabled)
1
F001
5
1
F001
10
1
F001
1
1
F192
1 (Full-Duplex)
1
F194
2 (1)
1
F194
2 (1)
1
F194
2 (1)
1
F194
2 (1)
1
F194
2 (1)
1
F194
2 (1)
1
F003
30000
1
F003
30000
1
F003
30000
1
F003
30000
1
F003
30000
1
F003
30000
1
F001
1440
1
F001
240
1
F003
0
1
F003
0
1
F003
0
1
F001
0
1
F001
120
1
F001
0
1
F001
2404
1
F102
0 (Disabled)
1
F001
0
1
F001
60
1
F003
30000
1
F003
30000
1
F003
30000
1
F003
30000
0.01
F001
100
1
F003
30000
1
F003
0
1
F126
0 (No)
1
F003
2130706433
1
F003
4294966272
1
F003
56554497
1
F192
1 (Full-Duplex)
1
F627
0 (None)
B-27