Table A–1: FLEXANALOG DATA ITEMS (Sheet 13 of 17)
ADDRESS
FLEXANALOG NAME
9672
PMU 3 I2 Mag
9674
PMU 3 I2 Angle
9675
PMU 3 I0 Mag
9677
PMU 3 I0 Angle
9678
PMU 3 Freq
9680
PMU 3 df dt
9681
PMU 3 Conf Ch
9686
PMU 4 Va Mag
9688
PMU 4 Va Angle
9689
PMU 4 Vb Mag
9691
PMU 4 Vb Angle
9692
PMU 4 Vc Mag
9694
PMU 4 Vc Angle
9695
PMU 4 Vx Mag
9697
PMU 4 Vx Angle
9698
PMU 4 V1 Mag
9700
PMU 4 V1 Angle
9701
PMU 4 V2 Mag
9703
PMU 4 V2 Angle
9704
PMU 4 V0 Mag
9706
PMU 4 V0 Angle
9707
PMU 4 Ia Mag
9709
PMU 4 Ia Angle
9710
PMU 4 Ib Mag
9712
PMU 4 Ib Angle
9713
PMU 4 Ic Mag
9715
PMU 4 Ic Angle
9716
PMU 4 Ig Mag
9718
PMU 4 Ig Angle
9719
PMU 4 I1 Mag
9721
PMU 4 I1 Angle
9722
PMU 4 I2 Mag
9724
PMU 4 I2 Angle
9725
PMU 4 I0 Mag
9727
PMU 4 I0 Angle
9728
PMU 4 Freq
9730
PMU 4 df dt
9731
PMU 4 Conf Ch
12306
Oscill Num Triggers
13504
DCmA Inputs 1 Value
13506
DCmA Inputs 2 Value
13508
DCmA Inputs 3 Value
13510
DCmA Inputs 4 Value
13512
DCmA Inputs 5 Value
13514
DCmA Inputs 6 Value
13516
DCmA Inputs 7 Value
13518
DCmA Inputs 8 Value
GE Multilin
N60 Network Stability and Synchrophasor Measurement System
UNITS
DESCRIPTION
Amps
Phasor measurement unit 3 negative-sequence current magnitude
Degrees
Phasor measurement unit 3 negative-sequence current angle
Amps
Phasor measurement unit 3 zero-sequence current magnitude
Degrees
Phasor measurement unit 3 zero-sequence current angle
Hz
Phasor measurement unit 3 frequency
Hz/s
Phasor measurement unit 3 rate of change of frequency
---
Phasor measurement unit 3 configuration change counter
Volts
Phasor measurement unit 4 phase A voltage magnitude
Degrees
Phasor measurement unit 4 phase A voltage angle
Volts
Phasor measurement unit 4 phase B voltage magnitude
Degrees
Phasor measurement unit 4 phase B voltage angle
Volts
Phasor measurement unit 4 phase C voltage magnitude
Degrees
Phasor measurement unit 4 phase C voltage angle
Volts
Phasor measurement unit 4 auxiliary voltage magnitude
Degrees
Phasor measurement unit 4 auxiliary voltage angle
Volts
Phasor measurement unit 4 positive-sequence voltage magnitude
Degrees
Phasor measurement unit 4 positive-sequence voltage angle
Volts
Phasor measurement unit 4 negative-sequence voltage magnitude
Degrees
Phasor measurement unit 4 negative-sequence voltage angle
Volts
Phasor measurement unit 4 zero-sequence voltage magnitude
Degrees
Phasor measurement unit 4 zero-sequence voltage angle
Amps
Phasor measurement unit 4 phase A current magnitude
Degrees
Phasor measurement unit 4 phase A current angle
Amps
Phasor measurement unit 4 phase B current magnitude
Degrees
Phasor measurement unit 4 phase B current angle
Amps
Phasor measurement unit 4 phase C current magnitude
Degrees
Phasor measurement unit 4 phase C current angle
Amps
Phasor measurement unit 4 ground current magnitude
Degrees
Phasor measurement unit 4 ground current angle
Amps
Phasor measurement unit 4 positive-sequence current magnitude
Degrees
Phasor measurement unit 4 positive-sequence current angle
Amps
Phasor measurement unit 4 negative-sequence current magnitude
Degrees
Phasor measurement unit 4 negative-sequence current angle
Amps
Phasor measurement unit 4 zero-sequence current magnitude
Degrees
Phasor measurement unit 4 zero-sequence current angle
Hz
Phasor measurement unit 4 frequency
Hz/s
Phasor measurement unit 4 rate of change of frequency
---
Phasor measurement unit 4 configuration change counter
---
Oscillography number of triggers
mA
DCmA input 1 actual value
mA
DCmA input 2 actual value
mA
DCmA input 3 actual value
mA
DCmA input 4 actual value
mA
DCmA input 5 actual value
mA
DCmA input 6 actual value
mA
DCmA input 7 actual value
mA
DCmA input 8 actual value
A.1 PARAMETER LISTS