GE N60 Instruction Manual page 447

Ur series network stability and synchrophasor measurement system
Hide thumbs Also See for N60:
Table of Contents

Advertisement

APPENDIX B
Table B–10: MODBUS MEMORY MAP (Sheet 5 of 65)
ADDR
REGISTER NAME
160E
Field Transducer Input Trouble States
Ethernet Fibre Channel Status (Read Only)
1610
Ethernet Primary Fibre Channel Status
1611
Ethernet Secondary Fibre Channel Status
1612
Ethernet Tertiary Fibre Channel Status
Data Logger Actual Values (Read Only)
1618
Data Logger Channel Count
1619
Time of Oldest Available Samples
161B
Time of Newest Available Samples
161D
Data Logger Duration
Sensitive Directional Power Actual Values (Read Only) (2 modules)
1680
Sensitive Directional Power 1 Power
1682
Sensitive Directional Power 2 Power
Field Unit RTD Actuals (Read Only) (8 modules)
16C0
Field RTD x Value
16C1
...Repeated for module number 2
16C2
...Repeated for module number 3
16C3
...Repeated for module number 4
16C4
...Repeated for module number 5
16C5
...Repeated for module number 6
16C6
...Repeated for module number 7
16C7
...Repeated for module number 8
Field Unit Transducer Actuals (Read Only) (8 modules)
16C8
Field Transducer x Value
16CA
...Repeated for module number 2
16CC
...Repeated for module number 3
16CE
...Repeated for module number 4
16D0
...Repeated for module number 5
16D2
...Repeated for module number 6
16D4
...Repeated for module number 7
16D6
...Repeated for module number 8
Frequency Rate of Change Actual Values (Read Only) (4 modules)
16E0
Frequency Rate of Change 1
16E1
Reserved (3 items)
16E4
...Repeated for Frequency Rate of Change 2
16E8
...Repeated for Frequency Rate of Change 3
16EC
...Repeated for Frequency Rate of Change 4
Source Current (Read Only) (6 modules)
1800
Source 1 Phase A Current RMS
1802
Source 1 Phase B Current RMS
1804
Source 1 Phase C Current RMS
1806
Source 1 Neutral Current RMS
1808
Source 1 Phase A Current Magnitude
180A
Source 1 Phase A Current Angle
180B
Source 1 Phase B Current Magnitude
180D
Source 1 Phase B Current Angle
180E
Source 1 Phase C Current Magnitude
1810
Source 1 Phase C Current Angle
1811
Source 1 Neutral Current Magnitude
1813
Source 1 Neutral Current Angle
1814
Source 1 Ground Current RMS
1816
Source 1 Ground Current Magnitude
1818
Source 1 Ground Current Angle
1819
Source 1 Zero Sequence Current Magnitude
GE Multilin
N60 Network Stability and Synchrophasor Measurement System
RANGE
UNITS
0 to 65535
---
0 to 2
---
0 to 2
---
0 to 2
---
0 to 16
channel
0 to 4294967295
seconds
0 to 4294967295
seconds
0 to 999.9
days
W
-2147483647 to 2147483647
-2147483647 to 2147483647
W
-32768 to 32767
°C
-32.768 to 32.767
---
-327.67 to 327.67
Hz/s
0 to 65535
---
0 to 999999.999
A
0 to 999999.999
A
0 to 999999.999
A
0 to 999999.999
A
0 to 999999.999
A
-359.9 to 0
degrees
0 to 999999.999
A
-359.9 to 0
degrees
0 to 999999.999
A
-359.9 to 0
degrees
0 to 999999.999
A
-359.9 to 0
degrees
0 to 999999.999
A
0 to 999999.999
A
-359.9 to 0
degrees
0 to 999999.999
A
B.4 MEMORY MAPPING
STEP
FORMAT
DEFAULT
1
F500
0
1
F134
0 (Fail)
1
F134
0 (Fail)
1
F134
0 (Fail)
1
F001
0
1
F050
0
1
F050
0
0.1
F001
0
1
F060
0
1
F060
0
1
F002
0
0.001
F004
0
0.01
F002
0
1
F001
0
0.001
F060
0
0.001
F060
0
0.001
F060
0
0.001
F060
0
0.001
F060
0
0.1
F002
0
0.001
F060
0
0.1
F002
0
0.001
F060
0
0.1
F002
0
0.001
F060
0
0.1
F002
0
0.001
F060
0
0.001
F060
0
0.1
F002
0
0.001
F060
0
B-13
B

Advertisement

Table of Contents
loading

Table of Contents