Hitachi WJ200-004M Quick Reference Manual page 65

Wj200 series
Hide thumbs Also See for WJ200-004M:
Table of Contents

Advertisement

Func.
Name
Code
C147
Logic output 2 operator
C148
Logic output 3 operand A
C149
Logic output 3 operand B
C150
Logic output 3 operator
C160
Input [1] response time
C161
Input [2] response time
C162
Input [3] response time
C163
Input [4] response time
C164
Input [5] response time
C165
Input [6] response time
C166
Input [7] response time
Multistage
speed/position
C169
determination time
Input Function Summary Table – This table shows all thirty-one intelligent input functions
at a glance. Detailed description of these functions, related parameters and settings, and
example wiring diagrams are in "Using Intelligent Input Terminals" on page 27.
Option
Terminal
Code
Symbol
00
FW
FORWARD Run/Stop
01
RV
Reverse Run/Stop
Multi-speed Select,
02
CF1
Bit 0 (LSB)
Multi-speed Select,
03
CF2
Bit 1
Multi-speed Select,
04
CF3
Bit 2
Multi-speed Select,
05
CF4
Bit 3 (MSB)
06
JG
Jogging
07
DB
External DC braking
Set (select) 2nd Motor
08
SET
Data
"C" Function
Applies a logic function to calculate
[LOG] output state,
Three options:
00...[LOG] = A AND B
01...[LOG] = A OR B
02...[LOG] = A XOR B
All the programmable functions
available for logic (discrete) outputs
except LOG1 to LOG3, OPO, no
Applies a logic function to calculate
[LOG] output state,
Three options:
00...[LOG] = A AND B
01...[LOG] = A OR B
02...[LOG] = A XOR B
Sets response time of each input
terminal, set range:
0 (x 2 [ms]) to 200 (x 2 [ms])
(0 to 400 [ms])
Set range is 0. to 200. (x 10ms)
Input Function Summary Table
Function Name
Description
Description
ON
Inverter is in Run Mode, motor runs forward
OFF
Inverter is in Stop Mode, motor stops
ON
Inverter is in Run Mode, motor runs reverse
OFF
Inverter is in Stop Mode, motor stops
ON
Binary encoded speed select, Bit 0, logical 1
OFF
Binary encoded speed select, Bit 0, logical 0
ON
Binary encoded speed select, Bit 1, logical 1
OFF
Binary encoded speed select, Bit 1, logical 0
ON
Binary encoded speed select, Bit 2, logical 1
OFF
Binary encoded speed select, Bit 2, logical 0
ON
Binary encoded speed select, Bit 3, logical 1
OFF
Binary encoded speed select, Bit 3, logical 0
Inverter is in Run Mode, output to motor runs at
ON
jog parameter frequency
OFF
Inverter is in Stop Mode
ON
DC braking will be applied during deceleration
OFF
DC braking will not be applied
The inverter uses 2nd motor parameters for
ON
generating frequency output to motor
The inverter uses 1st (main) motor parameters
OFF
for generating frequency output to motor
64
Run
Defaults
Mode
Initial data
Edit
00
00
01
00
1.
1.
1.
1.
1.
1.
1.
0.
msec.
Units