Hitachi WJ200-004M Quick Reference Manual page 28

Wj200 series
Hide thumbs Also See for WJ200-004M:
Table of Contents

Advertisement

Two Stage Acceleration and Deceleration
When terminal [2CH] is turned ON, the inverter
changes the rate of acceleration and
deceleration from the initial settings
F003) to use the second set of acceleration/
deceleration values. When the terminal is
turned OFF, the inverter is returned to the
original acceleration and deceleration time
(F002
acceleration time 1, and
deceleration time 1). Use
time 2) and
A093
the second stage acceleration and deceleration
times.
In the graph shown above, the [2CH] becomes active during the initial acceleration. This
causes the inverter to switch from using acceleration 1 (F002) to acceleration 2 (A092).
Option
Terminal
Code
Symbol
2CH
09
Valid for inputs:
Required settings
Notes:
Function
A094
selects the method for second
stage acceleration. It must be set =
the input terminal method in order for the [2CH]
terminal assignment to operate.
F003
A092
(acceleration
(deceleration time 2) to set
Function Name
Two-stage Accelera-
tion and
Deceleration
C001~C007
A092, A093,
A094=00
00
to select
(F002
and
Output
frequency
[2CH]
[FW,RV]
State
ON
Frequency output uses 2nd-stage acceleration and
deceleration values
OFF
Frequency output uses the initial acceleration 1 and
deceleration 1 values
Example (default input configuration shown see
page
59):
7
6
See I/O specs on
27
Target
frequency
second
initial
1
0
1
0
Description
2CH
5
4
3
2
1
L
page 16,17.
t
PCS
PLC
P24